4-66
System Administrator
4.5.5
System Parameter Settings
Value Range
(default)
Parameter
Description/Function
Reference
E.M.D.
Service
p.3-22
M.W.N.-
Device
p.3-38
Specifies the sequence of codes used by the VPS
to make a call to an outside line. You can set up
to 12 digits. The default value is ‘T’, which
means that the VPS dials the outside phone
numbers after detecting dial tone.
Outgoing Call
Setup Sequence
Up to 12 digits
consisting of
0–9, , #,
F, R, S,
T, W
(T)
Example:
9W = [9]
→
1-second wait
→
dial outside phone
number.
‘9’ is the CO line access number.
D : Disconnecting
F : Hook Flash
R : Ring Back Tone Detection
S : Silence Detection
T : Dial Tone Detection
W :Wait for 1 second
1–9, 0, , # : Dial Codes
4.5.5.6.3 Message Waiting Notification
The following parameters are used to control the handling of message notification
calls.
System Administration Top Menu
→
1
→
5
→
6
→
3
Program – System Parameter – Others – Message Waiting Notification Menu
Outgoing Call Ports -------------------------------------------------- :
1, 2, 3, 4
Message Waiting Lamp Ports ------------------------------------ :
1, 2, 3, 4
Message Waiting Lamp for Every Message ---------------- :
No
Max. Digits for Callback No. (1-48 digits) ------------------- :
20
Callback No. Entry Interdigit Time-Out (1-10 sec) -------- :
5
System Callback No. ------------------------------------------------ :
. . . . . . . . . . .
:
. . . . . . . . . . .
Содержание KX-TVP100
Страница 332: ...W 3 2 Worksheets See page 6 10 Message Manager Top Menu 3 Message Manager s Password Message Manager s Password ...
Страница 335: ...Worksheets W 3 5 See pages 6 12 6 13 Message Manager Top Menu 5 2 Company Name Company Name ...
Страница 341: ...Printed in Japan PSQX1052ZA IW0595Y0 Matsushita Electric Industrial Co Ltd Central P O Box288 Osaka 530 91 Japan ...