13.1 [11-1] Main—RS-232C—
Communication—Parity Bit
®
[800] RS-232C Parameter—Parity Bit
e.
Stop Bit Length:
A stop bit code indicates the end of a bit string which composes a character. Select
an appropriate value depending on the requirements of the PC or printer.
®
13.1 [11-1] Main—RS-232C—
Communication—Stop Bit
®
[800] RS-232C Parameter—Stop Bit Length
•
If a call is transferred to an ICD group using Automatic Transfer, the condition code "TR" will not be recorded
on SMDR (
®
1.12.1 Call Transfer).
[Host PBX Access Code]
•
The dialled number including the Host PBX Access code will be recorded on SMDR only if the modified
number setting is selected in the ARS setting for SMDR.
•
When a Host PBX Access code is assigned to a trunk group, calls to extensions of the host PBX are not
recorded on SMDR.
•
A Host PBX Access Code can be used to record only long distance calls on SMDR when a trunk port is
connected directly to the telephone company (not a host PBX). This is allowed when the long distance
code (e.g., "0") is assigned as the Host PBX Access code. All local calls (e.g., calls that do not require a
"0" to be dialled first) are treated as extensions of the telephone company and do not get recorded on
SMDR, because in this case this PBX recognises the telephone company as the host PBX. Therefore, only
long distance calls are recorded on SMDR.
[Output to a Telnet compatible Terminal Emulator]
•
In order to activate a connection to a terminal emulator, the IP address of the IPCMPR/IPCEMPR card,
port number, user ID ("SMDR"), and password must be entered.
•
If a terminal emulator user incorrectly enters the user ID or password 3 times consecutively, an alarm will
be sent and connection will not be possible for 10 minutes.
•
Through system programming, it is possible to assign the PBX port number and password.
•
For KX-TDE100/KX-TDE200 users:
The terminal emulator application must be running constantly. If the application is terminated, call records
that occur after the termination will be recorded in the PBX's memory. However, if the number of call records
exceeds the PBX's capacity, older records will be deleted. Also, when the application restarts or is
reconnected, duplicated call records may be output.
For KX-TDE600 users:
The terminal emulator application must be running constantly. If the application is terminated abnormally,
it can take up to 7 minutes for the PBX to detect the termination. Call records that occur after the termination
will be recorded in the PBX's memory. However, if the number of call records exceeds the PBX's capacity,
older records will be deleted.
Installation Manual References
KX-TDE100/KX-TDE200
3.13.1 Connection of Peripherals
KX-TDE600
3.3.3 IPCMEC Card (KX-TDE0105)
3.15.1 Connection of Peripherals
PC Programming Manual References
4.5 [2-3] Timers & Counters—Dial / IRNA / Recall / Tone—
Dial—Analogue CO Call Duration Start
4.12 [2-7-1] Class of Service—COS Settings—CO & SMDR—
Outgoing CO Call Printout (SMDR)
8.2 [6-2] Hotel & Charge
→Main—
SMDR for External Hotel Application 2—Printing Message 1–8
302
Feature Guide
1.26.1 Record Log Features
Содержание KX-TDE100
Страница 16: ...16 Feature Guide Table of Contents...
Страница 17: ...Section 1 Call Handling Features Feature Guide 17...
Страница 39: ...PT Programming Manual References 720 Doorphone Call Destination Feature Guide 39 1 1 2 Internal Call Features...
Страница 95: ...User Manual References 1 2 1 Basic Calling Feature Guide 95 1 5 4 Trunk Call Features...
Страница 127: ...User Manual References 1 2 4 When the Dialled Line is Busy or There is No Answer Feature Guide 127 1 8 3 Call Monitor...
Страница 160: ...Feature Guide References 1 20 2 Flexible Buttons 160 Feature Guide 1 11 6 Flash Recall Terminate...
Страница 162: ...User Manual References 1 10 4 If a Host PBX is Connected 162 Feature Guide 1 11 7 External Feature Access EFA...
Страница 175: ...User Manual References 1 4 2 Holding a Call Feature Guide 175 1 13 1 Call Hold...
Страница 187: ...1 7 2 Answering Denying a Paging Announcement Feature Guide 187 1 15 1 Paging...
Страница 238: ...Feature Guide References 1 30 4 QSIG Standard Features 238 Feature Guide 1 21 1 Integrated Services Digital Network ISDN...
Страница 287: ...Feature Guide References 3 1 Capacity of System Resources Feature Guide 287 1 25 2 PS Ring Group...
Страница 347: ...3 1 Capacity of System Resources User Manual References 1 2 1 Basic Calling Feature Guide 347 1 30 1 TIE Line Service...
Страница 383: ...User Manual References 1 14 1 Self Labelling KX NT366 only Feature Guide 383 1 31 4 Self Labelling KX NT366 only...
Страница 389: ...Section 2 System Configuration and Administration Features Feature Guide 389...
Страница 439: ...Section 3 Appendix Feature Guide 439...
Страница 453: ...Index Feature Guide 453...
Страница 459: ...Feature Guide 459 Notes...