1.5.4.6 Trunk Busy Out
Description
The PBX can monitor the loop current sent through analogue trunks, preventing users from seizing trunks
where a loop current is not detected. When loop currents are not detected, trunks are set to Busy Out status,
and become unable to make or receive calls. A trunk in Busy Out status cannot be used for making calls as a
TIE line, as part of a trunk group, or with the ARS feature, and cannot receive trunk calls. If a user tries to seize
a trunk set to Busy Out status, the user will hear a reorder tone.
This is useful if some or all trunks are occasionally unavailable because of problems with the external
telecommunications environment.
Conditions
•
Loop current detection is performed on active trunks whenever the trunk is seized and/or at fixed intervals.
•
When a trunk is in busy-out status, loop current detection is performed at fixed intervals, returning the trunk
to in-service status once a loop current is detected. An extension assigned as the manager can manually
change the trunk back to in-service status.
•
Trunk status changes are recorded in the error log of the PBX.
•
Busy Out status is maintained even when the PBX is reset.
•
Busy Out status is cleared when:
–
a call is successfully received (i.e., a loop current is detected) on that trunk.
–
the S-CO button for that trunk is pressed and a loop current is detected.
PC Programming Manual References
3.10 [1-1] Slot—Port Property - LCO Port—
4.8 [2-6-1] Numbering Plan—Main—Features—
4.11 [2-7-1] Class of Service—COS Settings—Programming & Manager—
4.17 [2-9] System Options—Option 5—
Busy Out—Busy Out for Analogue CO
PT Programming Manual References
Feature Guide References
User Manual References
2.1.6 Allowing Users to Seize an Unavailable Outside Line (Trunk Busy Out)
Feature Guide
93
1.5.4 Trunk Call Features
Содержание KX-TDA100D
Страница 7: ...VPS Voice Processing System X XDP EXtra Device Port Feature Guide 7 List of Abbreviations ...
Страница 13: ...Section 1 Call Handling Features Feature Guide 13 ...
Страница 35: ...PT Programming Manual References 720 Doorphone Call Destination Feature Guide 35 1 1 2 Internal Call Features ...
Страница 89: ...User Manual References 1 2 1 Basic Calling Feature Guide 89 1 5 4 Trunk Call Features ...
Страница 121: ...User Manual References 1 2 4 When the Dialled Line is Busy or There is No Answer Feature Guide 121 1 8 3 Call Monitor ...
Страница 154: ...Feature Guide References 1 20 2 Flexible Buttons 154 Feature Guide 1 11 6 Flash Recall Terminate ...
Страница 156: ...User Manual References 1 10 4 If a Host PBX is Connected 156 Feature Guide 1 11 7 External Feature Access EFA ...
Страница 168: ...User Manual References 1 4 2 Holding a Call 168 Feature Guide 1 13 1 Call Hold ...
Страница 367: ...Section 2 System Configuration and Administration Features Feature Guide 367 ...
Страница 409: ...Section 3 Appendix Feature Guide 409 ...
Страница 414: ...Item Capacity User Level Programmer Code 0 16 characters 414 Feature Guide 3 1 Capacity of System Resources ...
Страница 417: ...Index Feature Guide 417 ...
Страница 423: ...Feature Guide 423 Notes ...