Note
•
The no. 4 and no. 5 pins (Master) of the CS must be connected to a pair of pins on the DHLC/
DLC card. Then use 4 consecutive pairs of pins on the DHLC/DLC card, starting with the pins
corresponding to the Master, as in the example above.
•
When connecting multiple KX-TDA0158 CSs to a DHLC/DLC card, make sure that the no. 4 and
no. 5 pins (Master) of adjacent CSs are at least 3 pairs of pins away on the card.
•
For details about the DHLC/DLC card, refer to the Installation Manual for your PBX.
•
CS connections must be made within the same DHLC/DLC card.
•
When a wrong connection is made, satisfactory performance of the CS cannot be guaranteed.
Check the connection of CS and the PBX using the Maintenance Console. For information about
how to view CS information using the Maintenance Console, refer to "Utility—CS Information" in
the PC Programming Manual or the On-line Help for your PBX.
KX-TDA0155 connecting to KX-NCP500/KX-NCP1000
Note
The illustration of the PBX is based on the KX-NCP500.
Signal Name
DHLC/DLC card (RJ45)
Pin No.
1
2
3
4
5
6
7
8
D1
D2
1
2
3
4
D1
D2
CS (RJ11)
Pin No.
Signal Name
Cable
Maximum Distance
ø 0.4 mm:
222 m
ø 0.5 mm:
347 m
ø 0.6 mm:
500 m
CAT 5:
347 m
DHLC4 Card
Accessories and User-supplied Items for the CS
Accessories (included):
Screws
´
2, Washers
´
2
User-supplied (not included):
RJ11 connector
Note
For details about the DHLC/DLC card, refer to the Installation Manual for your PBX.
Quick Installation Guide
43
7 Connecting a Cell Station to the PBX