2-32
Installation
2.4.2 CO Line Connection
(KX-TD1232: CO1 through CO8)
Card Installation
To connect CO 1 through CO 8 to KX-TD1232, install the optional
8-CO Line Card (KX-TD181/KX-TD181D).
To connect four ISDN S0 lines to KX-TD1232, install the optional
4-ISDN S0 Line Card (KX-TD281).
1. Insert the upper end of the 8-CO Line Card or 4-ISDN S0 Line
Card into the two hooks on the main unit.
2. Press the two corners at the lower end of the Card.
3. Fix the card with an accessary screw at the lower-right corner.
4. Connect the cord to the connector.
Wire Specifications
In making a CO line connection, use twisted pair cable for
installation. The wire specifications for CO lines are as follows:
Wire
Solid wire
Diameter of conductor
ø 0.4 – ø 0.65 mm
Diameter including coating
ø 0.66 – ø 1.05 mm
Note
• In case of starting the system for the first time or System Data Clear,
the application for location will adapt the practical installation instead
of system default setting.
• System Programming is required for location identification. Refer to
Section 4, [109] “Expansion Card / Unit Type.”
Default: 8-CO Line Card
8-CO Line Card
4-pin Connector
✕
4
4-pin Connector
✕
1 (on the lower board)
4-ISDN S0 Line Card
Содержание KX-TD816AL
Страница 87: ......
Страница 219: ...Section 4 System Programming This section provides step by step programming instructions for a proprietary telephone ...
Страница 364: ...Section 5 List This section lists tone ring tone and default values of system programming ...
Страница 371: ...Section 6 Troubleshooting This section provides information for system and telephone troubleshooting ...
Страница 377: ...Matsushita Electric Industrial Co Ltd Central P O Box 288 Osaka 530 91 Japan Printed in Japan PQQX11289XA S1294MT3108CK ...