![Panasonic KX-TD816AL Скачать руководство пользователя страница 300](http://html1.mh-extra.com/html/panasonic/kx-td816al/kx-td816al_installation-manual_4025576300.webp)
4.6
CO Line Programming
CO Line Group Assignment
4-82
System Programming
401
Description
Each CO line must be assigned to a CO line group. This program
defines the CO line group assignment for each CO line. For
example, if there are multiple telephone service companies
available, the CO lines can be grouped by company.
Selection
• CO line (CO) number:
KX-TD816 – 01 through 08,
(
=all CO lines)
KX-TD1232 – 01 through 24,
(
=all CO lines)
• CO line group (TRG) number: 1 through 8
Default
CO01 – TRG 1;
CO05 – TRG 5;
CO02 – TRG 2;
CO06 – TRG 6;
CO03 – TRG 3;
CO07 – TRG 7;
CO04 – TRG 4;
CO08 – TRG 8 (for KX-TD816);
CO08 through CO24 – TRG 8 (for KX-TD1232)
Programming
1.
Enter 401.
Display : Trunk Group Asn
2.
Press NEXT.
Display: CO Line NO?–>
3.
Enter a CO line number.
To enter CO line number 01, you can also press NEXT.
Display example: CO01:TRG1
4.
Enter the CO line group number.
To change the current entry, enter the new CO line group number.
5.
Press STORE.
6.
To program another CO line, press NEXT or PREV, or
SELECT and the desired CO line number.
7.
Repeat steps 4 through 6.
8.
Press END.
Conditions
• In the case of KX-TD1232, CO01 through CO12 are for the Master
System and CO13 through CO24 are for the Slave, if available.
• To assign all CO lines to one CO line group, press the
key at step 3.
In this case, the display shows the contents programmed for CO01.
Feature References
Section 3, Features,
CO Line Group
Содержание KX-TD816AL
Страница 87: ......
Страница 219: ...Section 4 System Programming This section provides step by step programming instructions for a proprietary telephone ...
Страница 364: ...Section 5 List This section lists tone ring tone and default values of system programming ...
Страница 371: ...Section 6 Troubleshooting This section provides information for system and telephone troubleshooting ...
Страница 377: ...Matsushita Electric Industrial Co Ltd Central P O Box 288 Osaka 530 91 Japan Printed in Japan PQQX11289XA S1294MT3108CK ...