![Panasonic KX-TD816AL Скачать руководство пользователя страница 307](http://html1.mh-extra.com/html/panasonic/kx-td816al/kx-td816al_installation-manual_4025576307.webp)
4.6
CO Line Programming
Intercept Extension — Day / Night
System Programming
4-89
409-410
Description
Intercept Routing provides an automatic re-direction of calls which
cannot or have not been answered. These programs set the
destination in both day and night modes for each line group.
Selection
• CO line group (TRG) number: 1 through 8,
(
=all CO line groups)
• Extension number: 2 through 4 digits / Disable (no Intercept
Routing)
Default
All CO line groups – Disable — Day / Night
Programming
1.
Enter a program address (409 for day or 410 for night).
Display example: TRG Intercpt Day
2.
Press NEXT.
Display: TRK GRP NO?–>
3.
Enter the CO line group number.
To enter CO line group number 1, you can also press NEXT.
Display example: TRG1:Disable
4.
Enter an extension number.
To change the current entry, press CLEAR and the new number.
To disable Intercept Routing, press CLEAR.
5.
Press STORE.
6.
To program another CO line group, press NEXT or PREV, or
SELECT and the desired CO line group number.
7.
Repeat steps 4 through 6.
8.
Press END.
Conditions
• You set the extension numbers in program [003] “Extension Number
Set” or floating numbers of pagers in program [813] “Floating Number
Assignment.” You cannot assign the floating number of the modem.
• To assign all CO line groups to one selection, press the
key at step 3.
In this case, the display shows the contents programmed for CO line
group 1.
• Program [401] “CO Line Group Assignment” is used to assign each CO
line to a CO line group.
Feature References
Section 3, Features,
Intercept Routing
Содержание KX-TD816AL
Страница 87: ......
Страница 219: ...Section 4 System Programming This section provides step by step programming instructions for a proprietary telephone ...
Страница 364: ...Section 5 List This section lists tone ring tone and default values of system programming ...
Страница 371: ...Section 6 Troubleshooting This section provides information for system and telephone troubleshooting ...
Страница 377: ...Matsushita Electric Industrial Co Ltd Central P O Box 288 Osaka 530 91 Japan Printed in Japan PQQX11289XA S1294MT3108CK ...