background image

SafeLine

 

SL1

Installation manual

 ENGLISH  v2.01
10.2012

Emergency telephone for lifts. Complies to EN81-28 and
EN81-70 standards.

Содержание SL1

Страница 1: ...SafeLine SL1 Installation manual ENGLISH v2 01 10 2012 Emergency telephone for lifts Complies to EN81 28 and EN81 70 standards...

Страница 2: ...d by law safeline eu SafeLine SL1 ENGLISH v2 01 Technical data Power Supply voltage 10 30V DC Current consumption max 50mA Emergency signal button Can be set as NO or NC 10 30V DC Auxillary input Can...

Страница 3: ...tions 4 Overview 5 Measurements and component list 6 Wiring diagram 7 Wiring diagram parallel wiring 8 Configuration interfaces 9 Configuration method 10 10 Configuration unit numbers 11 Configuration...

Страница 4: ...and maintenance personnel The basis prerequisite for safe handling and trouble free operation of this system is a sound knowledge of the basic and special safety regulations concerning conveyor techno...

Страница 5: ...al Power emergency button phone line and auxilary inputs 2 rS232 Pc connection Firmware update and programming with SafeLine Pro 3 Keyboard Programming 4 Volume control Buttons 2 and 8 raises respecti...

Страница 6: ...9 27 95 ENGLISH v2 01 Installation Safeline Sl1 alarm button with microphone Article number LT Stat01 Safeline Sl1 coP Article number SL1 Safeline Sl1 alarm button microphone and speaker Article numbe...

Страница 7: ...se 8 7 6 5 4 3 2 1 ENGLISH v2 01 Installation WirinG diaGram Filter Alarm button Voltage supply 10 30V DC Voltage supply 0V Telephone line in Extra remote Extra emergency button External pictograms Ma...

Страница 8: ...se SL1 www safeline se SL1 www safeline se SL1 www safeline se ENGLISH v2 01 Installation Serial wiring daisy chain wiring Four wires required Parallel wiring Two wires required WirinG diaGram Safeli...

Страница 9: ...unit Programming with Safeline Pro The unit can be programmed at the office prior to the installation or at site after installation with a programming cable PCable remote programming For remote progr...

Страница 10: ...Remote configuration with external telephone 1 beep Alla SL1 answers 3 tones Requested unit answers 2 short beeps waiting for password Valid password Start programming Wrong password One long beep Mu...

Страница 11: ...ber 1 Program unit as number 1 9 End Programming Press the next unit number repeatedly until hearing 3 beeps Enter the password Terminate programming First unit answers The next unit answers Unit prog...

Страница 12: ...line call centre If at any time you need to start over use the factory reset command 99 1 confiGuraTion eXamPleS Safeline auTodialer uniTS Lift ID code each lift must have its own unique code 1 Start...

Страница 13: ...2 Q23 3 CPC change this only if your alarm operator is using any of the mentioned protocols Call type 2nd number 22 Call type 3rd number 23 Call type 4th number 24 Call type LMS number 30 LMS Lift Mo...

Страница 14: ...ergency signal in speaker 71 The speaker siren will sound at emergency call 1 On 0 Off Default Ring tone timeout 72 Number of ring signals before dialling the next number 8 by default Additional input...

Страница 15: ...end of alarm Break on new alarm 86 Disconnects a call longer than 60 seconds at new activation of the alarm button and calls the next emergency call number 0 OFF 1 ON Default Alarm button delay time...

Страница 16: ...n available flashing twice every second Calling out light steady Call connected flashing rapidly Incoming call yellow led call in progress The Yellow Pictogram LED is lit as soon as the alarm button i...

Страница 17: ...es 5 times Short tone in the speaker Green LED ashes every 5 sec if valid telephone line connected and set to standard Yellow LED ashes every 5 sec No connection Yellow LED ashes 5 times Long tone in...

Страница 18: ...inute Calling 2nd phone number Calling 4th phone number Calling 3rd phone number Line missing or busy Emergency alarm activated Receiving tone No No No No No Yes Yes Yes Yes Yes Answer Answer Answer A...

Страница 19: ...r check the microphone Poor distorted sound quality Volume might be set too loud Lower the volume and check again Interfering noise when the call is connected The problem might be due to induction in...