15
© 2012 SafeLine and all the SafeLine products and accessories are copyrighted by law.
ENGLISH v2.01
Programming
oTher codeS
code
daTa
commenTS
Indicator mode
*78*
- #
0 = Standard
1 = Strictly EN81-28
2 = Strictly single EN81-28
Voice communication time-out
*79*
- #
1 - 20 minutes. Standard = 8 min
Reset active alarm automatically
*80*
#
0 = OFF,
1 = ON (Default)
Auto answer
*81*
- - #
No of signals before SafeLine answers incoming call.
Can be set from 00-16 (Default = 02, 00=Unit will not answer).
Unit number
*82*
- #
Program Unit number 1-9 (Default = 0)
Detect dial tone
*83*
- #
0 = Off
1 = On (Default)
Set to off if SafeLine has problem to detect the dial tone.
Receipt to alarm receiver with
P100 protocol
*84*
- #
Select which message(s) to send to the alarm receiver at an alarm call.
0 = None (Default)
1 = Start of alarm
2 = Start+end of alarm
Break on new alarm
*86*
- #
Disconnects a call longer than 60 seconds at new activation of the alarm
button and calls the next emergency call number.
0 = OFF
1 = ON (Default)
Alarm button delay time
*87*
- - #
Delay time from pressing the alarm button until activating the alarm.
00-25 seconds. (Default = 05)
Alarm button type
*89*
- #
0 = Normally-open contact, NO (Default)
1 = Normally-closed contact, NC
Change password
*91*
- - - - #
Change password (default=0000)
Simulate an alarm event
*94*
- #
Triggers an alarm event after programming is terminated.
1 = Emergency call
2 = Test alarm
3 = Battery failure
4 = Microphone/Loudspeaker failure
5 =Receipt on voice call
6 = Maintenance
7 = Main unit power failure
8 = Stuck button alarm
Reset to default settings
*99*
- #
1 = Factory default
2 = Default P100(The following codes will be set):
*21*0#, *22*0#, * 27*03#, *80*1#, *84*1#, *88*1#
3 = Default CPC(The following codes will be set):
*21*3#, *22*3#, *27*03#, *80*1#, *84*1#, *88*1#
4 = Default VOICE(The following codes will be set):
*21*1#, *22*1#, * 27*03#, *80*1#, *84*1#, *88*1#