16
© 2012 SafeLine and all the SafeLine products and accessories are copyrighted by law.
ENGLISH v2.01
Operating
led indicaTion
yellow led
light off:
Telephone line OK, call
terminated
flashing once every 5
seconds:
Telephone line
not
OK.
flashing twice every second:
Emergency signal button
active.
yellow steady:
Activated alarm. Remains lit
until reset.
Green led
light off:
Telephone line
not
OK.
flashing once every 5
seconds:
Unit is OK. Phone line is OK.
flashing two times every 5
seconds:
Alarm fi lter activated.
Green steady
:
Call connected.
continuous fl ashing:
Telephone in confi
guration
mode.
System led
flashing once every 5
seconds:
Telephone line OK.
flashing two times every 5
seconds:
No telephone connection
available.
flashing twice every second:
Calling out
light steady:
Call connected.
flashing rapidly:
Incoming call.
yellow led “call in progress“
The Yellow Pictogram LED, is
lit as soon as the alarm button
is pressed longer than the set
delay
Standard (*78*0#)
Strictly en81-28 (*78*1#)
Green led “call connected“
The Green pictogram LED turns
on as soon as the SafeLine unit
detects a responding voice.
The LED is turned off when the
call is terminated.
yellow led
flashing twice every second:
Emergency signal button
active.
yellow steady:
Activated alarm. Remains lit
until reset.
Green led
Green steady
:
Call connected.
System led
The system LED is located on
the backside of the unit.
yellow led
flashing twice every second:
Emergency signal button
active.
yellow steady:
Activated alarm. Remains lit
until reset.
Strictly single (*78*2#)
As strictly EN81-28 except that the LEDs will not be lit simultaneously, but one at a time.