8.2.2
Site Planning
DECT Portable Station Section
8-7
Installation Preparation
1. Prepare a drawing of the building where you want to install the
Cell Station (CS).
(A drawing which shows the size or main structural material of
the wall, partition wall or ceiling is preferable.)
2. Consider the service area required for the users.
3. Examine the service area on the drawing.
1) Make a circle around the installable area by determining the
radio transmission range (inside: 25 – 50 m, outside: 70 – 100
m). Note that a CS cannot be installed outside a building.
2) If more than one CS is required, the radio transmission
ranges should overlap. The overlapping range should be at
least 5 to 10 meters.
<Basic location>
5 – 10 m
<Location example for a building
which has an object in the centre.>
CS
CS
Cell Stations
(KX-TD142)
Object