16
Chapter 6 Installation and Wiring
6-1 Panel Cut-out dimensions
(Unit: mm)
6-2 Panel mounting diagram
How to mount
From the panel front, pass the main unit through the square holes. Insert the mounting frame from the
rear and push it in so that the gap between the mounting frame and the panel surface is minimized.
Tighten the screws (2 places) equally tight and check that there is no rattling. If the screws are overly
tightened, the frame may come off. In that case, loosen the screws and tighten them again pushing the
frame in.
Dimension A when ‘u’ products are mounted in a row: A=(48
*
n-2.5)
If the products are mounted in a row, they lose their waterproofing properties.
+0.6
0