5-9
When using the SD memory card.
Data may be erased or the SD memory card may be damaged during the operation. Take measures for
the situations as below.
Problem
Measures
Data in SRAM
(Record area for
logging) is lost.
Transmitting GT configuration setting file using the logging function clears the
information on the SRAM.
Save all the data remained in the log before transmission.
When data cannot be saved in the SD memory card, the data beginning with the
chronologically oldest data will be overwritten if the record area for logging is full.
Make the setting of the notice device for the case that the SD card free space is
less than the specified size.
SD memory card is
damaged and data
cannot be read
because SD
memory card was
ejected during save.
Stop the logging of data.
Eject the SD memory card after turning on the setting for stopping the trigger
occurrence for all logging files in the record area control.
(Activate the setting for stopping the trigger occurrence with switch parts, etc.)
Set not to save in the SD memory card.
Turn on the control device for stopping write to the SD memory card, and then
eject the card.
SD memory card is
damaged by power
discontinuity due to
power failure and
data cannot be read
A UPS (Uninterruptible power source) is used. When using a UPS, the power is
supplied to the PLC and GT both from the UPS, and the signal for logging
stop/file creation is sent to the GT from the PLC using the power failure alarm
signal that is input into the PLC as a trigger. (See figure below.)
Содержание GT01
Страница 25: ...Chapter 1 Features and Functions ...
Страница 40: ...1 16 ...
Страница 41: ...Chapter 2 Names and Functions of Parts ...
Страница 42: ...2 2 2 1 Part Names 2 1 1 GT01 GT11 GT21 GT01 GT01R GT11 GT21 ...
Страница 44: ...2 4 2 1 2 GT02 GT02L GT02M2 GT02G2 GT02M0 GT02M1 GT02G0 GT02G1 GT02L ...
Страница 48: ...2 8 2 1 4 GT05 GT12 GT32 GT32 R GT32 E GT05 GT12 GT32 Standard High function ...
Страница 49: ...2 9 GT32 R GT32 E ...
Страница 62: ...2 22 ...
Страница 63: ...Chapter 3 Installation and Wiring ...
Страница 86: ...3 24 ...
Страница 87: ...Chapter 4 Connecting with PLC ...
Страница 108: ...4 22 Connecting to the 2 channel type RS485 Note Check the usable GT models for 1 N communication ...
Страница 122: ...4 36 ...
Страница 123: ...Chapter 5 Troubleshooting ...
Страница 141: ...Chapter 6 Specifications ...
Страница 187: ...Chapter 7 Dimensions and Other Documentation ...
Страница 188: ...7 2 7 1 Dimensions 7 1 1 GT01 GT01R Installation dimensions Panel cutout dimensions ...
Страница 189: ...7 3 7 1 2 GT02 Installation dimensions Panel cutout dimensions ...
Страница 190: ...7 4 7 1 3 GT02L Installation dimensions Panel cutout dimensions ...
Страница 191: ...7 5 7 1 4 GT03M E Installation dimensions Panel cutout dimensions ...
Страница 193: ...7 7 7 1 6 GT05 Installation dimensions Panel cutout dimensions ...
Страница 194: ...7 8 7 1 7 GT11 Installation dimensions Panel cutout dimensions ...
Страница 195: ...7 9 7 1 8 GT12 Installation dimensions Panel cutout dimensions ...
Страница 196: ...7 10 7 1 9 GT21 Installation dimensions Panel cutout dimensions ...
Страница 197: ...7 11 7 1 10 GT32 GT32M Back view GT32T0 GT32T1 Installation dimensions Panel cutout dimensions ...
Страница 198: ...7 12 7 1 11 GT32 R GT32 E Installation dimensions Panel cutout dimensions ...
Страница 199: ...7 13 7 2 Cable Specifications 7 2 1 AIGT8142 7 2 2 AIGT8152 7 2 3 AIGT8160 AIGT8162 AIGT8165 AIGT8192 ...
Страница 200: ...7 14 7 2 4 AIGT8175 7 2 5 AIP81842 ...
Страница 202: ...7 16 7 4 ASCII Code Table ...
Страница 205: ......