6-30
6.8 GT21
6.8.1 General Specifications (GT21)
Item
Specifications
Rated voltage
24 V DC
Operating voltage range
21.6 to 26.4 V DC
Power consumption
4.8 W or less (200 mA or less)
Ambient temperature
0 to +50
C
Note1)
Ambient humidity
20 to 85% RH (at 25
C), non-condensing
Storage temperature
-20 to +60
C
Storage humidity
10 to 85% RH (at 25
C), non-condensing
Breakdown voltage
Between [power supply terminals] and [case]
500 V AC for 1 minute, Cutoff current 10mA (at default setting)
Insulation resistance
Between [power supply terminals] and [case]
100 M
or more, 500 V DC, measured with megohmmeter (at default
setting)
Vibration resistance
10 to 55 Hz (1-minute cycle)
Amplitude: 0.75 mm,
10 min on 3 axes
Shock resistance
98 m/s
2
or more,
4 times on 3 axes
EC Directive applicable
EMC Directive: EN61000-6-2, EN61000-6-4
Noise immunity
1000 V [P-P] or more, Pulse width 50 ns, 1
s between power supply
terminals (based on in-house measurements)
Note2)
Protective construction
IP65 (Initial value, evaluated by us)
Dustproof and drip-proof from front panel only (packing used on panel
contact surface)
Note3)
Weight
Approx. 230 g
Note1) When it is installed in a horizontal orientation (installed to make the liquid crystal face be topside)
or when the FP programmer II or C-NET adapter is connected to the TOOL port, the usable
range is 0 to +45
C.
Note2) When using our exclusive cable.
Note3) When reattaching, replace waterproof packing.
Содержание GT01
Страница 25: ...Chapter 1 Features and Functions ...
Страница 40: ...1 16 ...
Страница 41: ...Chapter 2 Names and Functions of Parts ...
Страница 42: ...2 2 2 1 Part Names 2 1 1 GT01 GT11 GT21 GT01 GT01R GT11 GT21 ...
Страница 44: ...2 4 2 1 2 GT02 GT02L GT02M2 GT02G2 GT02M0 GT02M1 GT02G0 GT02G1 GT02L ...
Страница 48: ...2 8 2 1 4 GT05 GT12 GT32 GT32 R GT32 E GT05 GT12 GT32 Standard High function ...
Страница 49: ...2 9 GT32 R GT32 E ...
Страница 62: ...2 22 ...
Страница 63: ...Chapter 3 Installation and Wiring ...
Страница 86: ...3 24 ...
Страница 87: ...Chapter 4 Connecting with PLC ...
Страница 108: ...4 22 Connecting to the 2 channel type RS485 Note Check the usable GT models for 1 N communication ...
Страница 122: ...4 36 ...
Страница 123: ...Chapter 5 Troubleshooting ...
Страница 141: ...Chapter 6 Specifications ...
Страница 187: ...Chapter 7 Dimensions and Other Documentation ...
Страница 188: ...7 2 7 1 Dimensions 7 1 1 GT01 GT01R Installation dimensions Panel cutout dimensions ...
Страница 189: ...7 3 7 1 2 GT02 Installation dimensions Panel cutout dimensions ...
Страница 190: ...7 4 7 1 3 GT02L Installation dimensions Panel cutout dimensions ...
Страница 191: ...7 5 7 1 4 GT03M E Installation dimensions Panel cutout dimensions ...
Страница 193: ...7 7 7 1 6 GT05 Installation dimensions Panel cutout dimensions ...
Страница 194: ...7 8 7 1 7 GT11 Installation dimensions Panel cutout dimensions ...
Страница 195: ...7 9 7 1 8 GT12 Installation dimensions Panel cutout dimensions ...
Страница 196: ...7 10 7 1 9 GT21 Installation dimensions Panel cutout dimensions ...
Страница 197: ...7 11 7 1 10 GT32 GT32M Back view GT32T0 GT32T1 Installation dimensions Panel cutout dimensions ...
Страница 198: ...7 12 7 1 11 GT32 R GT32 E Installation dimensions Panel cutout dimensions ...
Страница 199: ...7 13 7 2 Cable Specifications 7 2 1 AIGT8142 7 2 2 AIGT8152 7 2 3 AIGT8160 AIGT8162 AIGT8165 AIGT8192 ...
Страница 200: ...7 14 7 2 4 AIGT8175 7 2 5 AIP81842 ...
Страница 202: ...7 16 7 4 ASCII Code Table ...
Страница 205: ......