5-9
Initialization information setting area 2 (bank 0)
Address
Name
Default
value
Setting value and explanation
210H
Receiving buffer starting address for transparent
communication (Connection 1)
2800H
[Set value] First address in receive
buffer.
- The first address of the receive
buffer is specified using the absolute
address (word address) of the
shared memory when transparent
communication is being carried out
among the various connections.
- FFFFH is set if this is not being
used.
211H
Receiving buffer size for transparent
communication (Connection 1)
0400H
[Set value] Size of receive buffer.
- The size of the receive buffer is
specified in word units when
transparent communication is being
carried out among the various
connections.
- 0000H is set if this is not being used.
212H
Transmission buffer starting address for
transparent communication (Connection 1)
2C00H
[Set value] First address in send
buffer.
- The first address of the send buffer
is specified using the absolute
address (word address) of the
shared memory when transparent
communication is being carried out
among the various connections.
- FFFFH is set if this is not being
used.
213H
Transmission buffer size for transparent
communication (Connection 1)
0400H
[Set value] Size of send buffer.
- The size of the send buffer is
specified in word units when
transparent communication is being
carried out among the various
connections.
- 0000H is set if this is not being used.
214H
Connection
2
Receiving buffer starting address for
transparent communication
3000H
- The first address in each buffer
should be specified using 2800H to
3FFFH (word address).
- For the details of each setting, refer
to the above “addresses 210H to
213H”.
215H
Receiving buffer size for transparent
communication
0400H
216H
Transmission buffer starting address
for transparent communication
3400H
217H
Transmission buffer size for
transparent communication
0400H
218H
Connection
3
Receiving buffer starting address for
transparent communication
3800H
219H
Receiving buffer size for transparent
communication
0400H
21AH
Transmission buffer starting address
for transparent communication
3C00H
21BH
Transmission buffer size for
transparent communication
0400H
21CH
Connection
4
Receiving buffer starting address for
transparent communication
FFFFH
21DH
Receiving buffer size for transparent
communication
0000H
21EH
Transmission buffer starting address
for transparent communication
FFFFH
21FH
Transmission buffer size for
transparent communication
0000H
Содержание FP2 ET-LAN
Страница 11: ...Chapter 1 Unit Functions and Restrictions ...
Страница 14: ...1 4 1 1 4 Connecting to a Network AFP2790 100BASE TX 10BASE T 10BASE5 AUI AFP27901 ...
Страница 24: ...1 14 ...
Страница 25: ...Chapter 2 Names and Functions of Parts ...
Страница 29: ...Chapter 3 Connection for LAN Cable ...
Страница 37: ...Chapter 4 Confirming the Design Contents ...
Страница 49: ...Chapter 5 Initialization Processing and Termination Processing ...
Страница 51: ...5 3 Operation of the ET LAN unit The relationship between initialization processing and open processing ...
Страница 68: ...5 20 ...
Страница 69: ...Chapter 6 Open Processing and Close Processing ...
Страница 71: ...6 3 Operation of the ET LAN unit The relationship between open processing and close processing ...
Страница 84: ...6 16 ...
Страница 85: ...Chapter 7 Computer Link Function ...
Страница 94: ...7 10 Program example ...
Страница 97: ...7 13 Example of communication data Same hierarchy communication ...
Страница 100: ...7 16 Example of communication data Other hierarchy communication ...
Страница 101: ...7 17 Other hierarchy communication for MEWTOCOL COM ...
Страница 102: ...7 18 ...
Страница 103: ...Chapter 8 Data Transfer Function ...
Страница 111: ...8 9 Program example ...
Страница 114: ...8 12 Example of communication data Same hierarchy communication ...
Страница 117: ...8 15 Example of communication data Other hierarchy communication ...
Страница 119: ...8 17 Other hierarchy communication for MEWTOCOL DAT ...
Страница 120: ...8 18 ...
Страница 121: ...Chapter 9 Transparent Communication Function ...
Страница 137: ...9 17 Program example ...
Страница 140: ...9 20 Reception processing After the following program has been run the received data is read from the receive buffer ...
Страница 141: ...9 21 9 5 3 Sample Program Reception to Transmission Program example for transmitting received data as it is ...
Страница 143: ...Chapter 10 Auto Connection ...
Страница 155: ...10 13 Case 1 Ladder program example ...
Страница 169: ...Chapter 11 E mail Function ...
Страница 200: ...11 32 ...
Страница 201: ...Chapter 12 Error Log Function ...
Страница 203: ...12 3 Latest log block area Log block reading processing area ...
Страница 219: ...Chapter 13 Troubleshooting ...
Страница 224: ...13 6 13 2 4 Troubleshooting Flowchart ...
Страница 225: ...13 7 ...
Страница 229: ...Chapter 14 MEWTOCOL Communication Procedure ...
Страница 241: ...14 13 WD Write data area This writes the contents of the data area To write the contents of DT LD and FL ...
Страница 242: ...14 14 To write to an index register ...
Страница 262: ...14 34 ...
Страница 263: ...Chapter 15 Specifications ...
Страница 292: ...15 30 15 6 ASCII Codes ...
Страница 293: ...15 31 15 7 Dimensions AFP2790 FP2 ET1 AFP27901 FP2 ET2 ...
Страница 294: ......
Страница 295: ...Chapter 16 Sample Program ...
Страница 298: ...16 4 ...
Страница 299: ...16 5 ...
Страница 300: ...16 6 ...
Страница 301: ...16 7 ...
Страница 304: ......
Страница 305: ......