10-9
10.1.5 Reading Auto Connection Information
When the auto connection is valid, the auto connection information can be read in the same block as the
connection information notified block of the conventional connection information notified area (Bank: 0,
Addresses: 2E0H to 35FH). Additionally, other than the conventional information, the following
information can be newly read.
- Auto connection information readout items
Offset
address
Name
Stored value/Explanation
0
Open processing
complete code
(Connections 1 to 8)
[Stored value]
0: Open processing has been completed successfully.
Other than 0: Error code (when open processing ended in an error)
When re-open processing is conducted, the results are overwritten.
Error codes are also stored in the error log area.
1
Source node port
No.
(Connections 1 to 8)
[Stored value]
Source node port numbers for various connections after open processing has
been completed.
▪
The value is not entered until open processing has been successfully
completed.
2
Destination node IP
address (L)
(Connections 1 to 8)
[Stored value]
Destination node IP addresses for various connections after open processing
has been completed.
▪
The value is not entered until open processing has been successfully
completed.
3
Destination node IP
address (H)
(Connections 1 to 8)
4
Destination node
port No.
(Connections 1 to 8)
[Stored value]
Destination node port No. for various connections after open processing has
been completed.
▪
The value is not entered until open processing has been successfully
completed.
5
Destination node
MEWTOCOL station
No.
(Connections 1 to 8)
[Stored value]
Destination node MEWTOCOL station numbers for various connections after
open processing has been completed.
▪
The value is not entered until open processing has been successfully
completed.
6
Connection closing
time
(Connections 1 to 8)
[Stored value]
Connection is closed when no communication is performed during the time
specified here.
▪
The value is not entered until initialization processing has been successfully
completed.
7
Re-opening
information
(Connections 1 to 8)
[Stored value]
Number of
re-open times remained
▪
The value is not entered until initialization processing has been successfully
completed.
Specified No. of re-open times: The specified number of re-open times is stored.
No. of re-open times remained: The number of re-open times remained is stored.
8
Communication
method
Opening method
Application in which
connection is used
(Connections 1 to 8)
[Stored value]
1-word data that sets the communication conditions for the
various connections as bit information.
For details, refer to 6.2.3 “Writing Data to the Connection Information Setting
Area” of the “ET-LAN Unit Technical Manual.”
▪
The value is not entered until initialization processing has been successfully
completed.
9
Reserved
Reserved (Used in the system.)
Содержание FP2 ET-LAN
Страница 11: ...Chapter 1 Unit Functions and Restrictions ...
Страница 14: ...1 4 1 1 4 Connecting to a Network AFP2790 100BASE TX 10BASE T 10BASE5 AUI AFP27901 ...
Страница 24: ...1 14 ...
Страница 25: ...Chapter 2 Names and Functions of Parts ...
Страница 29: ...Chapter 3 Connection for LAN Cable ...
Страница 37: ...Chapter 4 Confirming the Design Contents ...
Страница 49: ...Chapter 5 Initialization Processing and Termination Processing ...
Страница 51: ...5 3 Operation of the ET LAN unit The relationship between initialization processing and open processing ...
Страница 68: ...5 20 ...
Страница 69: ...Chapter 6 Open Processing and Close Processing ...
Страница 71: ...6 3 Operation of the ET LAN unit The relationship between open processing and close processing ...
Страница 84: ...6 16 ...
Страница 85: ...Chapter 7 Computer Link Function ...
Страница 94: ...7 10 Program example ...
Страница 97: ...7 13 Example of communication data Same hierarchy communication ...
Страница 100: ...7 16 Example of communication data Other hierarchy communication ...
Страница 101: ...7 17 Other hierarchy communication for MEWTOCOL COM ...
Страница 102: ...7 18 ...
Страница 103: ...Chapter 8 Data Transfer Function ...
Страница 111: ...8 9 Program example ...
Страница 114: ...8 12 Example of communication data Same hierarchy communication ...
Страница 117: ...8 15 Example of communication data Other hierarchy communication ...
Страница 119: ...8 17 Other hierarchy communication for MEWTOCOL DAT ...
Страница 120: ...8 18 ...
Страница 121: ...Chapter 9 Transparent Communication Function ...
Страница 137: ...9 17 Program example ...
Страница 140: ...9 20 Reception processing After the following program has been run the received data is read from the receive buffer ...
Страница 141: ...9 21 9 5 3 Sample Program Reception to Transmission Program example for transmitting received data as it is ...
Страница 143: ...Chapter 10 Auto Connection ...
Страница 155: ...10 13 Case 1 Ladder program example ...
Страница 169: ...Chapter 11 E mail Function ...
Страница 200: ...11 32 ...
Страница 201: ...Chapter 12 Error Log Function ...
Страница 203: ...12 3 Latest log block area Log block reading processing area ...
Страница 219: ...Chapter 13 Troubleshooting ...
Страница 224: ...13 6 13 2 4 Troubleshooting Flowchart ...
Страница 225: ...13 7 ...
Страница 229: ...Chapter 14 MEWTOCOL Communication Procedure ...
Страница 241: ...14 13 WD Write data area This writes the contents of the data area To write the contents of DT LD and FL ...
Страница 242: ...14 14 To write to an index register ...
Страница 262: ...14 34 ...
Страница 263: ...Chapter 15 Specifications ...
Страница 292: ...15 30 15 6 ASCII Codes ...
Страница 293: ...15 31 15 7 Dimensions AFP2790 FP2 ET1 AFP27901 FP2 ET2 ...
Страница 294: ......
Страница 295: ...Chapter 16 Sample Program ...
Страница 298: ...16 4 ...
Страница 299: ...16 5 ...
Страница 300: ...16 6 ...
Страница 301: ...16 7 ...
Страница 304: ......
Страница 305: ......