12.5 MEWTOC OL-COM Communication Commands
Table of MEWTOCOL-COM commands
Command name
Code
Description
Read contact area
RC
(RCS)
(RCP)
(RCC)
Reads the on and off status of contact.
- Specifies only one point.
- Specifies multiple contacts.
- Specifies a range in word units.
Write contact area
WC
(WCS)
(WCP)
(WCC)
Turns contacts on and off.
- Specifies only one point.
- Specifies multiple contacts.
- Specifies a range in word units.
Read data area
RD
Reads the contents of a data area.
Write data area
WD
Writes data to a data area.
Read timer/counter set value area
RS
Reads the value set for a timer/counter.
Write timer/counter set value area
WS
Writes a timer/counter setting value.
Read timer/counter ellapsed value area
RK
Reads the timer/counter elapsed value.
Write timer/counter elapsed value area
WK
Writes the timer/counter elapsed value.
Register or Reset contacts monitored
MC
Registers the contact to be monitored.
Register or Reset data monitored
MD
Registers the data to be monitored.
Monitoring start
MG
Monitors a registered contact or data using the
code “MC or MD”.
Preset contact area (fill command)
SC
Embeds the areaof a specified range in a 16-
point on and off pattern.
Preset data area (fill command)
SD
Writes the same contents to the data area of a
specified range.
Read system register
RR
Reads the contents of a system register.
Write system register
WR
Specifies the contents of a system register.
Read the status of PLC
RT
Reads the specifications of the programmable
controller and error codes if an error occurs.
Remote control
RM
Switches the operation mode of the
programmable controller.
Abort
AB
Aborts communication.
Содержание FP E Series
Страница 1: ......
Страница 16: ......
Страница 17: ...Chapter 1 Functions and Restrictions of the Unit ...
Страница 28: ...1 12 ...
Страница 29: ...Chapter 2 Specifications and Functions of the Unit ...
Страница 37: ...2 9 Circuit diagram C32 Y0 Y1 Y3 Y4 C28 Y0 Y1 Y3 Y4 Y2 Y5 to YF Y2 Y5 to YB ...
Страница 48: ...2 20 ...
Страница 49: ...Chapter 3 Expansion ...
Страница 56: ...3 8 Terminal layout diagram Note The numbers in the connector are for the first expansion ...
Страница 61: ...Chapter 4 I O Allocation ...
Страница 66: ...4 6 ...
Страница 67: ...Chapter 5 Installation and Wiring ...
Страница 90: ...5 24 ...
Страница 91: ...Chapter 6 High speed counter Pulse Output and PWM Output functions ...
Страница 116: ...6 26 ...
Страница 121: ...6 31 ...
Страница 125: ...6 35 Pulse output diagram ...
Страница 131: ...6 41 ...
Страница 139: ...6 49 ...
Страница 141: ...6 51 ...
Страница 144: ...6 54 Program Continued on the next page ...
Страница 145: ...6 55 ...
Страница 147: ...6 57 Program ...
Страница 151: ...Chapter 7 Communication Cassette ...
Страница 202: ...7 52 Procedure of communication In the following example the Micro Imagechecker is connected to COM1 port ...
Страница 210: ...7 60 The values of DT50 and DT51 are written in DT0 and 1 of PLC ...
Страница 238: ...7 88 ...
Страница 239: ...Chapter 8 Self Diagnostic and Troubleshooting ...
Страница 247: ......
Страница 248: ......
Страница 249: ...Chapter 9 Precautions During Programming ...
Страница 260: ...9 12 Example 2 Using the CT instruction between JP and LBL instructions ...
Страница 268: ...9 20 ...
Страница 269: ...Chapter10 Specifications ...
Страница 286: ......
Страница 287: ...Chapter 11 Dimensions ...
Страница 290: ...11 4 11 1 3 Expansion Unit FPG XY64D2T FPG XY64D2P FPG EM1 ...
Страница 293: ...Chapter 12 Appendix ...
Страница 297: ...12 5 ...
Страница 437: ...12 145 12 7 ASCII Codes ...
Страница 439: ......
Страница 440: ......