VXR70H
7
Confirmation and
preparation
Humidity indicator
nanoe
®
indicator
Clean sign
ECONAVI indicator
Human activity sensor
indicator
Check indicator
Front indication
■
nanoe
®
indicator
●
The indicator is lit when nanoe
®
is generated.
(It turns on in all operating modes.)
●
nanoe
®
operation can be turned off. (P.23 Q18)
■
Water supply indicator
●
If there is no more water in the tank when
humidification is set, a beeping notification sound is
emitted and the “Water supply indicator”
blinks.
→
Fill the tank with water. (P.9)
●
When the “Water supply indicator”
is blinking,
the product operates without any humidification.
■
Check indicator
●
When the abnormality occurs in the products, the
indicator is lit.
→
When the indicator is lit. (P.25 )
■
Humidity indicator
●
The indicators are lit even when operation is stopped.
(The displayed humidity is just an approximate value,
which may differ from the figure displayed on your
hygrometer.)
Appropriate humidity (Lit green)
Low humidity
(Lit red)
High humidity
(Lit red)
Water supply indicator
PM 2.5 detection indicator
Human activity
sensor
Dust indicator
Odor indicator
Filter replacement notification indicator
The “Clean sign” notifies how dirty the air is, and each
sign indicates the type of dirt present.
The sensitivity of the sensor can be changed. (P.22 Q8)
■
Clean sign
(Blue): indicates the air is clean.
(Red·1): indicates the air is
slightly dirty.
(Red·3): indicates the air is
dirty.
■
PM 2.5 detection indicator
PM 2.5 detection is indicated by the indicator
turning on or flashing.
(PM 2.5 includes cigarette smoke, dust and other
contaminants of 2.5 μm or less.)
●
The “PM 2.5 detection indicator” turns on when
PM 2.5 is detected in the air in the room. If the
concentration level of PM 2.5 is high, the “PM 2.5
detection indicator” flashes, and an audible alarm
(ping ping ping) will beep during operation.
●
To immediately remove PM 2.5,
press
. (P.13)
■
Dust indicator
It turns on when dust is detected.
■
Odor indicator
It turns on when odors are detected.
*Depending on the dirt present, only the “Clean sign”
may turn on red without any other indicator turning on.
■
Human activity sensor (
P.5)
Detects and notifies the actions of people with a sign
(the indicator lit).
The sensitivity of the sensor can be changed. (P.23 Q13)
■
ECONAVI indicator
●
The indicator is lit during ECONAVI mode (P.21).
●
ECONAVI mode can be turned off. (P.23 Q17)
■
Filter replacement notification indicator
●
The replacement timing for the HEPA composite
filter and deodorizing filter are notified with the
indicator lit. When the indicator turns on, it is time to
replace the HEPA composite filter and deodorizing
filter, so please replace the filters. (P.8 to 9)
After replacing the filters, press and hold
and
simultaneously for
3 seconds to reset the product. (The indicator is
turned off.) If the product is not reset, it will stop
operating 1 week after the indicator turns on.