24
Humidifying filter, Filter frame
<about once a month
*
1
>
(based on operation of 8 hours every day)
■
Humidifying filter
Press and wash in water or warm water
)below about 40 °C).
■
Filter frame
Wash with water.
●
Do not scrub with brush or do not wash with washing machine.
●
Do not dry with dryer. (It may cause shrinkage.)
●
If the humidifying filter is to be used immediately after washing,
it can be installed while still wet. If the product is going to be
stored, ensure that the humidifying filter has dried out
sufficiently before putting it back into the product.
●
Do not scrub the ion sterilization unit
(anti-fungus agent containing) with brush,
or do not apply excessive force to it.
●
Do not disassemble the ion sterilization
unit (anti-fungus agent containing).
●
If it is hard to remove the dirt or smell, please immerse the heavily stained filter and filter frame in warm
water containing the neutral detergent for kitchen purpose or in the solution of citric acid for about 30
minutes, then wash for 2 to 3 times with clean water.
●
Only when cleaning the humidifying filter, you can use the oxygen-based bleaching agent. For use amount, follow its
instructions.
Reference time for the humidifying filter replacement
(Service parts: P.38)
Replacement period
Conditions
●
After replacement, write the date installing the filter on the label and
stick it on the back of the product.
●
Dispose the used filter as inflammable garbage. Do not discard the filter frame.
About once every
10 years*
2
Based on 8 hours
operation daily
*2 The service life of the humidifying filter varies depending on water quality. In any of the following cases, replace it.
●
Odor is not removed after cleaning.
●
The water in the tray does not decrease.
●
It is seriously damaged.
When idle for a long time
Disconnect the power plug. (The product consumes power even at rest.)
Empty the tray and clean all the parts.
Dry their interiors completely. (Otherwise, the product may fail due to rust.)
●
Dry the humidifying filter completely in the shade. (Otherwise, fungus may occur.)
Cover the product with poly bag, and keep in dry places. (Do not keep it laid down or upside down, otherwise, failure may occur.)
How to remove
How to assemble
Lift the filter frame while pressing the lock portion.
●
Supporting the humidifying filter to avoid it from
falling out, hold the filter frame.
Turn over the filter frame.
Align the
humidifying filter to
the guides of the
filter frame and
insert it thoroughly.
Fold the tray handle
to the opposite side
of the floater.
(If you fold the handle
to the floater side,
you cannot install the
filter frame.)
While holding the humidifying filter, install the filter
frame to the tray. (Push the frame until it clicks.)
Note
●
The ion sterilization unit (anti-fungus agent containing) may have powder. This is normal and
it performs without problem.
●
The anti-fungus agent will become smaller over time. This is normal and it performs without problem.
●
The anti-fungus agent has a peculiar smell. It is not harmful.
Lock portion
Humidifying filter
/ Filter frame
Care and maintenance
Lock portion
Ion sterilization unit
(anti-fungus agent containing)
Humidifying
filter
Filter frame
Stitched side (blue line come
inside)
Guide
Tray