5.
At the power meter, measure the peak power.
6.
If measured power is in the range of the target power, then proceed to step 10.
7.
At the Channel box, press F7 to view the TRIM for the mid-channel.
Figure 6.14: Power level view 1
8.
Select VIEW TRIM PL MCH, and make a note of this value.
Figure 6.15: Power level 2
9.
Perform the following calculation and make a note of the result:
New Trim Value = Old Tri (Required Power - Measured Power) x Change per dB