276
APR 2002
Edition 2.0
DP-1510P/1810P
/1810F/2010E
029 REMOTE
DIAGNOSTICS
1 = Off (will not accept)
2 = On (accepts)
Selects whether the machine accepts Remote
Diagnostics from the service station.
030 CED & 300 bps
1 = 75 ms
2 = 1 sec
Selects the pause interval between the CED and the
300 bps signal.
(Used when Echo Suppression is disabled.)
031 RTC = EOLx12
1 = Off (EOLx6)
2 = On (EOLx12)
Selects the RTC signal, EOLx6 or EOLx12.
032 V34 TX START
2400-33600bps
Selects the transmission modem start speed for V.34
communication, 33600-2400 bps.
033 V34 RX START
2400-33600bps
Selects the receiving modem start speed for V.34
communication, 33600-2400 bps.
034 V34 TX Symbol
Rate
2400-3429sr
Selects the transmission symbol rate for V.34, 3429/
3200/3000/2800/2400 sr.
Press “V” or “/\ “ to select the symbol rate.
035 V34 RX Symbol
Rate
2400-3429sr
Selects receiving symbol rate for V.34, 3429/3429/
3200/3000/2800/2400 sr.
Press “V” or “/\ “ to select the symbol rate.
036 Not Used
037 PROTOCOL
DISPLAY
1 = Off (not displayed)
2 = On (displayed)
Selects whether to display the modem speed during
communication.
(Press the Job Status Key to display)
038 Not Used
039 FLASH TIME
5 = 50 ms
~
100 = 1000 ms
Selects the pause interval before activating the Flash
key.
040 E/F TIME
(For Germany,
Austria and
Switzerland only)
5 = 50 ms
~
100 = 1000 ms
Selects the pause interval before activating the Flash
key.
041 PAUSE TIME
1 = 1 sec.
~
10 = 10 sec.
Selects the pause interval from 1 sec. ~ 10 sec. for
dialing through a switchboard or for international
calls.
042 Not Used
043 REDIAL
INTERVAL
0 = no waiting
~
15 = 15 minutes
Selects the redial interval from 0 to 15 minutes in 1
minute steps.
044 REDIAL COUNT 0 = no redial
~
15 = 15 times
Selects the redial count from 0 to 15 times in 1 step
intervals.
Note:
In order to comply with the requirements TBR21
in the EC countries, do not select 15 times.
045 RING DETECT
COUNT
1 = 1 ring
~
9 = 9 rings
Selects the ring detection count from 1 to 9 rings in 1
ring step intervals.
046 ON-HOOK TIME 0 = 0 sec.
~
90 = 90 sec.
Selects the on-hook time between sequential
communication calls in 1 second step intervals.
047 RESPONSE
WAIT
1 = 1 sec.
~
90 = 90 sec.
Selects the waiting interval for the response after
completing the dialing.
Function Parameter Table
No.
Parameter
Selections
Function
Содержание DP-1510P
Страница 2: ...2 The contents of this Service Manual are subject to change without notice Published in Japan ...
Страница 74: ...74 APR 2002 Edition 2 0 DP 1510P 1810P 1810F 2010E 14 Remove the Cleaner Roller 640 14 ...
Страница 83: ...83 DP 1510P 1810P 1810F 2010E APR 2002 Edition 2 0 29 Remove 2 Developer Felts 1041 29 ...
Страница 158: ...158 APR 2002 Edition 2 0 DP 1510P 1810P 1810F 2010E 3 9 PNL2 PC Board CN20 Refer to PNL6 1 PC Board CN1 ...
Страница 184: ...184 APR 2002 Edition 2 0 DP 1510P 1810P 1810F 2010E 3 17 ILS PC Board CN750 Refer to LPC3 PC Board CN703 ...
Страница 187: ...187 DP 1510P 1810P 1810F 2010E APR 2002 Edition 2 0 3 20 SNS PC Board CN41 Refer to ADF PC Board CN28 ...
Страница 193: ...193 DP 1510P 1810P 1810F 2010E APR 2002 Edition 2 0 3 24 LANC PC Board CN200 Refer to LANB PC Board CN5 and CN6 ...
Страница 194: ...194 APR 2002 Edition 2 0 DP 1510P 1810P 1810F 2010E 3 25 EP PC Board CN1 Refer to SC PC Board CN121 ...
Страница 289: ...289 DP 1510P 1810P 1810F 2010E APR 2002 Edition 2 0 Fuser Error Detection ...
Страница 485: ...memo ...