236
APR 2002
Edition 2.0
DP-1510P/1810P
/1810F/2010E
495
XMT
RCV
C
During reception, CD turned OFF
or continued ON for long time.
During communication, lost loop -
current.
Line is disconnected.
Transmitter is defective.
SC PCB or MJR PCB is defective.
496
XMT
C
CS of modem is not able to turn
ON.
SC PCB is defective.
501
XMT/
RCV(V.34)
B
Remote unit does not have
compatible Modem.
502
XMT/
RCV(V.34)
B, C, D During reception, CD turned OFF
or continued ON for long time.
During communication, lost loop -
current.
Line is disconnected.
Transmitter is defective.
SC PCB or MJR PCB is defective.
503
XMT/
RCV(V.34)
B, C, D CS of modem is not able to turn
ON during training.
SC PCB is defective.
Line is disconnected.
504
RCV/V.34
(Polling)
B
Polling is rejected from the remote
station.
No polling original is set.
505
XMT/V.34
(Polling)
B
Polling XMT is rejected.
No polling original is set.
540
XMT ECM
B
No response after transmitting 3rd
CTC or DCN received.
Incompatible interface.
541
XMT ECM
D
No response after transmitting 3rd
EOR or received DCN.
Line is faulty.
MJR PCB abnormal.
542
XMT ECM
D
No response to the 3rd RR
transmitted or received DCN.
Remote unit is abnormal.
543
XMT ECM
D
T5 timer (60 sec.) elapsed without
MCF.
Remote unit is abnormal.
544
XMT ECM
D
Stopped Transmission after EOR
Transmission.
Line is faulty.
MJR PCB abnormal.
550
RCV ECM
C
Timer between frames in phase C
has elapsed.
Defective remote station.
554
RCV ECM
D
Transmitted ERR after receiving
EOR.
Faulty line.
555
RCV ECM
D
Transmitted PIN after receiving
EOR.
Faulty line and Operator Call requested
by RX side.
570
RCV
B
Password or machine code did not
match during remote diagnostic
communication.
571
XMT
B
Remote unit did not have the
remote diagnostic function.
580
XMT
B
Sub-address transmission to a unit
that has their DIS bit 49 (NSF bit
155) OFF.
Sub-address transmission to a unit that
has no Sub-address function.
581
XMT
B
Sub-address Password
transmission to a unit that has their
DIS bit 50 (NSF bit 156) OFF.
Sub-address transmission to a unit that
has no Sub-address function.
601
XMT
ADF Door was opened during ADF
transmission.
623
XMT
A
No original was in the ADF. (Built-
in dialer engaged)
Operator removed the original from the
ADF after dialing was completed.
Original was not set properly in the ADF.
Fax Information Codes
Code
Mode
Phase
Description of Problem
Cause
Содержание DP-1510P
Страница 2: ...2 The contents of this Service Manual are subject to change without notice Published in Japan ...
Страница 74: ...74 APR 2002 Edition 2 0 DP 1510P 1810P 1810F 2010E 14 Remove the Cleaner Roller 640 14 ...
Страница 83: ...83 DP 1510P 1810P 1810F 2010E APR 2002 Edition 2 0 29 Remove 2 Developer Felts 1041 29 ...
Страница 158: ...158 APR 2002 Edition 2 0 DP 1510P 1810P 1810F 2010E 3 9 PNL2 PC Board CN20 Refer to PNL6 1 PC Board CN1 ...
Страница 184: ...184 APR 2002 Edition 2 0 DP 1510P 1810P 1810F 2010E 3 17 ILS PC Board CN750 Refer to LPC3 PC Board CN703 ...
Страница 187: ...187 DP 1510P 1810P 1810F 2010E APR 2002 Edition 2 0 3 20 SNS PC Board CN41 Refer to ADF PC Board CN28 ...
Страница 193: ...193 DP 1510P 1810P 1810F 2010E APR 2002 Edition 2 0 3 24 LANC PC Board CN200 Refer to LANB PC Board CN5 and CN6 ...
Страница 194: ...194 APR 2002 Edition 2 0 DP 1510P 1810P 1810F 2010E 3 25 EP PC Board CN1 Refer to SC PC Board CN121 ...
Страница 289: ...289 DP 1510P 1810P 1810F 2010E APR 2002 Edition 2 0 Fuser Error Detection ...
Страница 485: ...memo ...
Страница 486: ...DZZSM00163 1 ...