![Panasonic DP-1510P Скачать руководство пользователя страница 235](http://html.mh-extra.com/html/panasonic/dp-1510p/dp-1510p_service-manual_257050235.webp)
235
DP-1510P/1810P
/1810F/2010E
APR 2002
Edition 2.0
415
XMT
(Polling)
B
Remote side attempted to receive
message from your machine in
polling communication.
Inform the remote side that your
machine does not have the polling
transmission feature.
416
RCV
D
Receiver did not detect post
command, such as EOP, MPS,
EOM, etc.
Transmitter is defective.
Line quality is poor. (RTC signal is
distorted due to line noise)
SC PCB or MJR PCB is defective.
417
RCV
C
Receiver returned RTN in
response to post message.
Line quality is poor. (There are
excessive errors in received data)
SC PCB or MJR PCB is defective.
418
RCV
C
Receiver transmitted PIN in
response to PRI-Q from
transmitter. (Transmitting operator
requests voice contact)
Line quality is poor. (There are
excessive errors in received data)
SC PCB or MJR PCB is defective.
420
RCV
B
T1 timer (35 sec.) elapsed without
detecting 300 bps signal.
There is wrong incoming call.
(Non-facsimile communication)
Transmitter is defective.
SC PCB or MJR PCB is defective.
421
RCV
B
Busy Tone is detected after
sending NSF Signal.
Remote station disconnected the line.
Wrong number is dialed.
422
XMT
B
Content of NSF (or DIS) or NSC
(or DTC) was invalid.
There is an incompatibility.
427
G3
RCV
B
DCN received to NSF/CSI/DIS
transmitted.
The interface is incompatible.
433
XMT
RCV
B, D
T.30 Protocol abnormal.
Defective remote station.
434 XMT or RCV
B
CD (response from Modem) did
not turn OFF within 180 sec. after
receiver detected FLAG signal.
Remote unit is defective.
SC PCB or MJR PCB is defective.
436
G3 RX
C
DCN received after transmitting
FTT.
Transmitter is defective or incompatible.
Line quality is poor.
456
RCV
B
Received relay transfer request or
confidential document to distribute
to an end receiving station or all
confidential mailboxes are used.
457
RELAY XMT
CONF. XMT/
POLL
B
Remote unit does not have
Relayed XMT or Confidential
Comm. capability.
459
RCV
C
Failed training in Phase C.
Line quality is poor. (Training signal is
distorted due to line noise)
SC PCB or MJR PCB is defective.
490
RCV
C
Sum of error lines exceeded the
limit (Function Parameter No. 70)
of 64 lines.
Line quality is poor.
SC PCB or MJR PCB is defective.
494
RCV
C
Interval between two EOLs was
more than 10 sec. when receiver
received message data.
Transmitter is defective.
Line quality is poor. (EOL is damaged
due to line noise)
SC PCB or MJR PCB is defective.
Fax Information Codes
Code
Mode
Phase
Description of Problem
Cause
Содержание DP-1510P
Страница 2: ...2 The contents of this Service Manual are subject to change without notice Published in Japan ...
Страница 74: ...74 APR 2002 Edition 2 0 DP 1510P 1810P 1810F 2010E 14 Remove the Cleaner Roller 640 14 ...
Страница 83: ...83 DP 1510P 1810P 1810F 2010E APR 2002 Edition 2 0 29 Remove 2 Developer Felts 1041 29 ...
Страница 158: ...158 APR 2002 Edition 2 0 DP 1510P 1810P 1810F 2010E 3 9 PNL2 PC Board CN20 Refer to PNL6 1 PC Board CN1 ...
Страница 184: ...184 APR 2002 Edition 2 0 DP 1510P 1810P 1810F 2010E 3 17 ILS PC Board CN750 Refer to LPC3 PC Board CN703 ...
Страница 187: ...187 DP 1510P 1810P 1810F 2010E APR 2002 Edition 2 0 3 20 SNS PC Board CN41 Refer to ADF PC Board CN28 ...
Страница 193: ...193 DP 1510P 1810P 1810F 2010E APR 2002 Edition 2 0 3 24 LANC PC Board CN200 Refer to LANB PC Board CN5 and CN6 ...
Страница 194: ...194 APR 2002 Edition 2 0 DP 1510P 1810P 1810F 2010E 3 25 EP PC Board CN1 Refer to SC PC Board CN121 ...
Страница 289: ...289 DP 1510P 1810P 1810F 2010E APR 2002 Edition 2 0 Fuser Error Detection ...
Страница 485: ...memo ...
Страница 486: ...DZZSM00163 1 ...