(2) If abnormalities as mentioned below are found during use, please do not use the Unit and contact your authorized dealer
immediately.
1)
Water leakage.
2)
No water flow.
3)
Water temperature cannot be controlled.
4)
ELB lamp does not light up.
(3) Special skill is required for repairing. Never try to repair the Unit by yourself.
(1) Check the following points before asking for repair.
Symptom
Points to be checked
1. Check the Filter Unit. Clean the Filter if it is clogged by stain and dirt (refer Filter Unit Cleaning at page 6).
2. Check the Shower Head and Shower Plate. Clean the Shower Head and Shower
Plate if it is clogged by dirt (refer Shower Head Cleaning at page 6).
1. Make sure the Main Switch Knob is at “On” position.
2. Make sure the ELB Reset Lever is not slide down.
Push up the ELB Reset Lever to reset the ELB (refer to TEST OPERATION at page 11).
3. Make sure to switch on the ON/OFF DP (double pole) Switch.
4. Make sure to switch on the Miniature Circuit Breaker (MCB).
1. Check the Water Volume Knob. Turn the Water Volume Knob clockwise if it is closed.
2. Check the Main Water Valve. Turn "ON" the Main Water Valve if it is closed (refer to HOW TO USE at page 5).
1. Check the WATER FLOW RATE ADJUSTMENT as in page 5.
Water is not drawn normally.
No hot water comes out from
the outlet
(no electric supply to the unit)
No water flows out from the
Shower Head at all.
Water not hot enough.
5. SPECIFICATIONS
230 V a.c. 60 Hz
3500 W
Inlet Water Temp. (Off), 1000 W - 3500 W
9.8 kPa / 0.1 k
g
f/cm² / 1.42 psi
380 kPa / 3.87 k
g
f/cm² / 55 psi
295(H) mm X 154(W) mm X 82(D) mm
1.2 k
g
Single Point System (Open Outlet)
Voltage
Power Consumption
Electric Power Control
Min. Water Pressure
Max. Water Pressure
Dimension
Weight
Outlet System
4. TROUBLESHOOTING