- 9 -
Wall Plug
Wall Plug
Screw
Wall
Wall
Back Plate
Back Plate
⑤
• Mount the Unit on the wall with 4 screws.
• Drive each Screw into the two upper Wall Plugs through
the screw holes on the Back Plate.
• After tighten up the two upper
Screws, tighten up the
remaining two Screws.
⑥
Please ensure the set fixed tightly on the wall by shaking
it left and right.
Note: The Back Plate must be
mounted with 4 Screws.
④
Lead the Flexible Cord to the set thru portion as shown below for electric wiring process.
⑤
④
⑥
Flexible Cord must enter the Unit thru
designated point only (do not make
additional holes).
CAUTION
①
The distance of the Unit should be more than 250 mm
from right and left of the wall.
Screw
Screw
Wall
Wall
250 mm
minimum
250 mm
minimum
②
Make 4 holes at the wall by means of a drill.
③
Drive a Wall Plug into the hole.
3. How to fix Electric Home Shower.
25 mm
View from outside
View from inside
Ø6 mm
Wall Plug
①
②
③
4. Electric wiring
Main Power Board
Earth
Tester
Power-Supply
Terminals
①
Lead the Flexible Cord connected to ELB terminal inside the unit:
2.5 mm², 3 core Flexible Cord.
②
Unscrew the Cord Holder and fix the Flexible Cord. Strip the lead
wire (coating). Fasten the life wire (L) and neutral wire (N) to the
ELB (L,N) and earth wire to the Ground Point with 1 N•m (10 k
g
f.cm)
torque. Fix back the Cord Holder to its position to clamp the
Flexible Cord.
③
Connect wires in correct polarity (L,N).
• Connecting the wires in wrong polarity (L,N) causes an abnormal
condition which may lead to electric leaking, burning and such.
• Before wiring, please check polarity (L,N) with voltage range
of a tester or voltmeter by connecting one terminal of the meter
to earth while the other to one of the
Power-Supply Terminals.
• When the needle of the meter
deflects greatly, the polarity of
the Power-Supply Terminals is ‘L’.
Bath Room
Earth
ON/OFF DP
(double pole) Switch
Miniature Circuit
Breaker (MCB)
Flexible Cord 2.5 mm², 3 core
L
N
Flexible Cord
75 mm
57 mm
13 mm
13 mm
1 N•m
Ground
Point
L N
WARNING
MUS
T BE TIGHTENED
1 N•m
Cord Holder
L N
WARNING
MUST BE TIGHTENED
1 N•m
L N
Proper size of Flexible Cord and electric wiring must be installed to avoid
smoke emission and fire hazards.
The home shower must be permanently connected to the electric supply
through the ON/OFF DP (double pole) Switch having a contact separation
of at least 3 mm in all poles incorporated in the fixed wiring. This switch
must be clearly identifiable but out of reach of a person using a fixed bath
or shower.
WARNING
WARNING
98.5 mm
80 mm
18.5 mm
250 mm
4 mm
254 mm
5 mm
L N
WA
RNING
MUST
B
E
TIG
HT
EN
ED
1 N
•
m
BEFORE USING