- 11 -
2. • Turn “ON” the Main Water Valve.
• Turn the Water Volume Knob clockwise.
• Check if water leaks from the Pipe Line.
3. • Turn the Main Switch Knob “On” (ELB lamp will lights).
• Turn the Power Control Knob clockwise and hot water will flow out from the Shower Head.
(Adjust to suitable water temperature).
4. • Refer detail for HOW TO USE and WATER FLOW RATE ADJUSTMENT on page 5.
1. • Before switch “ON” electricity supply check the wiring.
• Switch “ON” the Miniature Circuit Breaker (MCB) and ON/OFF DP (double pole) Switch.
• Set the ELB of the Unit to “On”. (Push up the ELB Reset Lever if it is down)
• Push the ELB Test Button.
• It is normal if the ELB turns “Off” (the ELB Reset Lever falls) and push the ELB Reset Lever up.
Refer figure as shown.
• Inspection on the built-in ELB (once a month) to avoid a hazard to users such as damage to
property, serious injury or death.
L N
WARNING
MU
ST BE TI
GH
TENED
1 N•m
Front Plate
Back Plate
“D-Cut”
Position
Main Switch Knob
and Power Control Knob
Front
Plate
Back
Plate
Press
Press
①
Make sure the Main Switch Knob and Power Control Knob on
Front Plate and it is at “Off” position.
②
Make sure the “D-Cut” position of the Rotary Shaft and VR Shaft
are located as shown.
③
Close the Front Plate of the unit according to the sequence as illustrated.
④
Push in the Main Switch Knob and Power Control Knob until it is fully inserted
<Main Switch Knob and Power Control Knob can not be inserted if
Step
①
and Step
②
is not done accordingly>
⑤
Fix the screw at the bottom of the Unit.
Note:
1. Do not push the ELB Test Button during fixing the Front Plate.
2. Do not apply extreme force to insert the Main Switch Knob
and Power Control Knob during fixing the Front Plate
because it will damage the switch inside the Unit.
6. How to fix the Front Plate
①
②
③
④
⑤
Screw
ELB
Po
wer Control
Mai
n Switch
ELB
Off
Off
High
On
ELB Test
ELB Reset
Push Up
3. TEST OPERATION
If the ELB Reset Lever cannot be reset even if you push it up or if it soon slides down
during operation, please do not use the Unit and contact the authorized dealer
immediately to avoid a hazard to users such as damage to property, serious injury or
death. Never fix the ELB Reset Lever forcibly with tape and such.
WARNING
Push
ELB
Test Button
ELB
Reset Lever
7. Shower Hanger installation.
Install the Shower Hanger so that the Shower Head top is not higher than the Unit top.
Shower Head
Shower Hanger
Screw
Wall Plug
Screw
Shower Hanger
OP
EN
CL
O
SE
FILTER
CLEANING
OF
F
MAX
ELB Test
ELB Reset
Push Up
Po
wer Control
Mai
n Switch
ELB
Off
Off
High
On
OP
EN
CL
OS
E
FILTER
CLEANING
OFF
MAX
ELB Test
ELB Reset
Push Up
Powe
r Contro
l
Main Switch
ELB
Off
Off
High
On
BEFORE USING