1.   HOW TO USE

Do not block the Shower Head with hand, towel 

or bend the Shower Hose.  The water flow rate will 

drop and water temperature may become very hot.

CAUTION

1.  Turn the Water Volume Knob clockwise to turn on the water (make sure the Main Water Valve is on).

 

(Water will flow out from Shower Head at inlet water temperature).

2.  Switch on the Miniature Circuit Breaker (MCB) and ON/OFF DP (double pole) Switch.

3.  Push up the ELB Reset Lever if it is down.

4.  Turn the Main Switch Knob to "On" (ELB Lamp will light).

5.  The shower temperature can be gradually controlled by turning the Power Control Knob.

 

If the Power Control Knob is turned clockwise, the shower temperature will increase, reaching the highest 

 

temperature at 'High'.

 

•  If the Water Volume Knob is turned clockwise, the volume of water will increase thus the water 

 

  temperature will decrease.

 

•  If the Water Volume Knob is turned anticlockwise, the volume of water will decrease thus the water 

 

  temperature will increase. (Please refer WATER FLOW RATE ADJUSTMENT below).

6.  After using this Unit, please turn off the Main Switch Knob and turn off the water supply by turning the 

 

Water Volume Knob anticlockwise until water flow is completely stop.

(1) Maximum water flow rate can be adjusted by using Main Water Valve.

 

Step 1:  Turn "OFF" the Main Water Valve.

 

Step 2:  Turn the Shower Head upward at waist height.

 

Step 3:  Turn the Water Volume Knob clockwise to maximum volume position.

 

Step 4:  Gradually turn "ON" the Main Water Valve and adjust the splashing height (H) of the shower. 

          

It is recommended to adjust the water splashing height (H) at 100 cm - 110 cm (approximately 3 L/min).

Note:  1. After setting maximum flow rate, please use Water Volume Knob to turn on and turn off the water supply. 

 

 

2. Pay attention to shower temperature when reducing the volume of water. 

 

 

  The shower temperature will become very hot if the water flow rate is too low. 

 

 

3. In case of continuous usage at high temperature setting, water temperature will increase and the control device 

 

 

  will activate temporary resulting the water temperature to drop.

Floor

Water Volume 

Knob

Main Water 

Valve

H = 100 cm - 110 cm

Waist Height

2.   WATER FLOW RATE ADJUSTMENT

Note: In case of no water supply, close the Water Volume Knob by turning it anticlockwise and make 

 

  sure the Main Switch Knob and the Power Control Knob are in "Off" condition (ELB light is off). 

 

  This is to prevent unnecessary water flow from Shower Head after the water supply recovered.

ELB: On condition

ELB: Off condition

ELB Test

ELB Reset

Push Up

Po

wer Control

Mai

n Switch

ELB

Off

Off

High

On

ELB Test

ELB Reset

Push Up

Po

wer Control

Mai

n Switch

ELB

Off

Off

High

On

O

PE

N

CL

O

SE

FILTER
CLEANING

OFF

MAX

ELB Test

ELB Reset

Push Up

Pow

er Control

Mai

n Switch

ELB

Off

Off

High

On

BEFORE USING

Содержание DH-3PL1PH

Страница 1: ...e Shower This appliance is intended for household use only For optimum performance and safety please carefully read this Operating Instructions and keep this documentation in a safe place for future reference DH 3PL1 Model No O P E N C L O S E FILTER CLEANING ELB Test ELB Reset Push Up OFF MAX Power Control Main Switch ELB Off Off High On ...

Страница 2: ...carefully To prevent personal injury injury to others and property damage the following instructions must be followed Incorrect operation caused by failure to follow instructions will cause harm or damage the seriousness of which is classified as follow SAFETY INSTRUCTIONS To be followed absolutely CONTENTS Page No BEFORE USING ELECTRIC HOME SHOWER 1 SAFETY INSTRUCTIONS 2 PARTS IDENTIFICATION 3 AC...

Страница 3: ...ectric home shower Unit to avoid physical and electric shock hazards If the ELB Reset Lever cannot be reset even if you push it up or if it soon slides down during operation please do not use the Unit and contact the authorized dealer immediately to avoid a hazard to users such as damage to property serious injury or death Never fix the ELB Reset Lever forcibly with tape and such Do not replace th...

Страница 4: ...Filter Body Packing OPEN C L O S E FILTE R CLEANIN G OFF MA X O P EN C L O S E FIL TE R CLE AN ING O F F M A X O P E N C L O S E FILTER CLEANING OFF MAX ELB Test ELB Reset Push Up Power Control Main Switch ELB Off Off High On O P E N C L O S E FILTER CLEANING OFF MAX ELB Lamp Filter Body Assembly Installation การติดตั งชิ นส วนประกอบตัวเครื องกรอง Place Rubber Packing between Filter Body Assembly ...

Страница 5: ...alve Step 1 Turn OFF the Main Water Valve Step 2 Turn the Shower Head upward at waist height Step 3 Turn the Water Volume Knob clockwise to maximum volume position Step 4 Gradually turn ON the Main Water Valve and adjust the splashing height H of the shower It is recommended to adjust the water splashing height H at 100 cm 110 cm approximately 3 L min Note 1 After setting maximum flow rate please ...

Страница 6: ...an it with moist cloth 2 Never use benzene thinner detergent bleach and such 3 Do not spray water to the Unit nor put wet towels on it 4 Make sure to use suitable cloth to clean the Front Plate surface to avoid scratch 2 Shower Head cleaning Turn the Shower Plate anticlockwise and remove it from the Shower Head with hand Clean the Shower Head s holes by using a soft brush from time to time Recomme...

Страница 7: ... down Push up the ELB Reset Lever to reset the ELB refer to TEST OPERATION at page 11 3 Make sure to switch on the ON OFF DP double pole Switch 4 Make sure to switch on the Miniature Circuit Breaker MCB 1 Check the Water Volume Knob Turn the Water Volume Knob clockwise if it is closed 2 Check the Main Water Valve Turn ON the Main Water Valve if it is closed refer to HOW TO USE at page 5 1 Check th...

Страница 8: ...outlet inlet water cannot be filtered and allows foreign particles to enter the Unit It will cause Heater Unit and Shower Head to clog up Do not install remove and reinstall the Unit by yourself Improper installation will cause leakage electric shock or fire Installation and wiring must be done by competent personnel Do not share the inlet and outlet pipe of the Home Shower Unit with other outlets...

Страница 9: ... N to the ELB L N and earth wire to the Ground Point with 1 N m 10 kgf cm torque Fix back the Cord Holder to its position to clamp the Flexible Cord Connect wires in correct polarity L N Connecting the wires in wrong polarity L N causes an abnormal condition which may lead to electric leaking burning and such Before wiring please check polarity L N with voltage range of a tester or voltmeter by co...

Страница 10: ...all or tiles If the Adjust Holder needs to be cut due to different wall height make sure the Adjust Holder is touching to the wall or tiles to prevent possibility of water leakage at the Filter Body Assembly Touching to the wall tiles wall tiles Touching to the wall tiles tiles tiles Cut Adjust Holder About 5 mm The Unit must be earthed Earth Rod fixing procedure Select suitable place to bury the ...

Страница 11: ...ng to the sequence as illustrated Push in the Main Switch Knob and Power Control Knob until it is fully inserted Main Switch Knob and Power Control Knob can not be inserted if Step and Step is not done accordingly Fix the screw at the bottom of the Unit Note 1 Do not push the ELB Test Button during fixing the Front Plate 2 Do not apply extreme force to insert the Main Switch Knob and Power Control...

Страница 12: ... Manufacturing Malaysia Berhad 2019 H0919Z1 20621 Panasonic Manufacturing Malaysia Berhad 196501000304 No 3 Jalan Sesiku 15 2 Section 15 Shah Alam Industrial Site 40200 Shah Alam Selangor Darul Ehsan Malaysia http www panasonic com ...

Отзывы: