11. Installation
Instruction
11.1 Select The Best Location
(For S28MKQ only)
11.1.1 Indoor
Unit
•
Do not install the unit in excessive oil fume area
such as kitchen, workshop and etc.
•
There should not be any heat source or steam
near the unit.
•
There should not be any obstacles blocking the air
circulation.
•
A place where air circulation in the room is good.
•
A place where drainage can be easily done.
•
A place where noise prevention is taken into
consideration.
•
Do not install the unit near the door way.
•
Ensure the spaces indicated by arrows from the
wall, ceiling, fence or other obstacles.
•
Recommended installation height for indoor unit
shall be at least 2.5m.
11.1.2 Outdoor
Unit
•
If an awning is built over the unit to prevent direct
sunlight or rain, be careful that heat radiation from
the condenser is not obstructed.
•
There should not be any animal or plant which
could be affected by hot air discharged.
•
Keep the spaces indicated by arrows from wall,
ceiling, fence or other obstacles.
•
Do not place any obstacles which may cause a
short circuit of the discharged air.
•
If piping length is over the [piping length for
additional gas], additional refrigerant should be
added as shown in the table.
If the unit is installed at 15 m distance, the quantity of
additional refrigerant should be 150 g …. (15-10) m x
30 g/m = 150 g.
11.1.3 Indoor/Outdoor Unit Installation
Diagram
Содержание CS-S12MKQ
Страница 11: ...11 3 Location of Controls and Components 3 1 Indoor Unit 3 2 Outdoor Unit 3 3 Remote Control ...
Страница 15: ...15 4 2 3 CU S18MKQ CU S24MKQ ...
Страница 16: ...16 4 2 4 CU S28MKQ ...
Страница 17: ...17 5 Refrigeration Cycle Diagram 5 1 CS S9MKQ CU S9MKQ CS S12MKQ CU S12MKQ ...
Страница 18: ...18 5 2 CS S18MKQ CU S18MKQ CS S24MKQ CU S24MKQ CS S28MKQ CU S28MKQ ...
Страница 19: ...19 6 Block Diagram 6 1 CS S9MKQ CU S9MKQ ...
Страница 20: ...20 6 2 CS S12MKQ CU S12MKQ ...
Страница 21: ...21 6 3 CS S18MKQ CU S18MKQ CS S24MKQ CU S24MKQ ...
Страница 22: ...22 6 4 CS S28MKQ CU S28MKQ ...
Страница 33: ...33 8 2 Outdoor Unit 8 2 1 CU S9MKQ ...
Страница 37: ...37 9 Printed Circuit Board 9 1 Indoor Unit 9 1 1 Main Printed Circuit Board ...
Страница 38: ...38 9 1 2 Power Printed Circuit Board 9 1 2 1 CS S9MK CS S12MK 9 1 2 2 CS S18MK CS S24MK ...
Страница 40: ...40 9 1 6 Comparator Printed Circuit Board 9 1 7 Human Activity Sensor Printed Circuit Board ...
Страница 41: ...41 9 2 Outdoor Unit 9 2 1 Main Printed Circuit Board 9 2 1 1 CU S9MK ...
Страница 42: ...42 9 2 1 2 CU S12MK ...
Страница 43: ...43 9 2 1 3 CU S18MK CU S24MK ...
Страница 44: ...44 9 2 1 4 CU S28MK ...
Страница 45: ...45 9 2 2 Noise Filter Printed Circuit Board 9 2 2 1 CU S9MKQ ...
Страница 115: ...115 Figure 3 Figure 4 Figure 5 16 1 1 3 To remove discharge grille Figure 6 ...
Страница 116: ...116 16 1 1 4 To remove control board Figure 7 16 1 1 5 To remove cross flow fan and indoor fan motor Figure 8 Figure 9 ...
Страница 117: ...117 Figure 10 Figure 11 ...
Страница 119: ...119 16 2 1 3 To remove power electronic controller Figure 14 Figure 15 Figure 16 Figure 17 ...
Страница 121: ...121 Figure 21 Figure 22 Figure 23 ...