14.11.1.3 Judge Ambient Condition
According to sunlight intensity over a period of time, the system will analyze the ambient condition is sunny,
cloudy or night.
14.11.1.4 Temperature
Shift
Set
temperature
HEAT
COOL/DRY
+1 °C
-1 °C
-1 °C
Ambient condition
Mode
ECONAVI
; Detecting sunlight intensity, the unit adjust temperature to save energy.
Night/Cloudy
Sunny
Sunny
In a room without window or with thick curtain, the sunlight sensor will judge as cloudy/night.
14.11.1.5 Sunlight
Sensor Check Mode
To enable sunlight sensor check mode, during unit is OFF (power standby):
iCOMFiAUTO-XHEATCOOLDRYFAN
F
SHOWER
DIRECT
AM
PM
AM
ON
OFF
PM
SET
Transmit ECO demo code and
after 30 seconds return to normal
mode.
Press continously for 5s
Transmit check code
and after 30 seconds return to normal
mode.
Transmit sunlight sensor check code
and after 30 seconds return to normal
mode.
Remote control normal mode
Operation details
o
The sunlight sensor check mode will be operated for 5 minutes.
o
During check mode, the ON and OFF timer will be memorized but it operation be ignored.
o
During check mode, if the sunlight sensor check code is retransmitted, the 5 minutes counter will be reset.
o
During check mode, if sunlight sensor detected the sunlight intensity value above minimum level, the
ECONAVI indicator turns ON. Else if sunlight sensor detected sunlight intensity value below minimum level,
the ECONAVI indicator is OFF.
To disable sunlight sensor check mode
o
After check mode is ended (5 minutes counter elapsed), press AUTO OFF/ON button at indoor unit.
o
If the sunlight sensor detected sunlight intensity is at abnormal range, the check mode will be ended.