12.2 Indoor Unit
12.2.1 How to Fix Installation Plate
The mounting wall shall be strong and solid enough to prevent it from vibration.
3
4
5
6
Wall
Wall
Wall
Installation plate
1
2
screw
More than
More than
Indoor unit
128 mm
241.5 mm
128 mm
More
than
For best strength of
INDOOR unit installation,
it is highly recommended
to locate “ ” at 5 position
as shown.
Measuring
Tape
1
1
2
Model
Dimension
HZ9***, AZ9***
HZ12***
or
490 mm
82 mm
435 mm
435 mm
127 mm
88 mm
The center of installation plate should be at more than
at right and left of the wall.
The distance from installation plate edge to ceiling should more than
.
From installation plate center to unit’s left side is
.
From installation plate center to unit’s right side is
.
○
B
: For left side piping, piping connection for liquid should be about
from this line.
: For left side piping, piping connection for gas should be about
from this line.
1 Mount the installation plate on the wall with 5 screws or more (at least 5 screws).
(If mounting the unit on the concrete wall, consider using anchor bolts.)
o
Always mount the installation plate horizontally by aligning the marking-off line with the thread and using
a level gauge.
2 Drill the piping plate hole with ø70 mm hole-core drill.
o
Line according to the left and right side of the installation plate. The meeting point of the extended line is
the center of the hole. Another method is by putting measuring tape at position as shown in the diagram
above. The hole center is obtained by measuring the distance namely 128 mm for left and right hole
respectively.
o
Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor
side.
12.2.2 To Drill a Hole in the Wall and
Install a Sleeve of Piping
1 Insert the piping sleeve to the hole.
2 Fix the bushing to the sleeve.
3 Cut the sleeve until it extrudes about 15 mm
from the wall.
CAUTION
When the wall is hollow, please be sure to use the
sleeve for tube assembly to prevent dangers
caused by mice biting the connection cable.
4 Finish by sealing the sleeve with putty or
caulking compound at the final stage.
15 mm
Putty or caulking compound
ø70 mm through hole
Indoor
Outdoor
Sleeve
for tube
assembly
Wall
Approx. 5 - 7 mm
Bushing for tube
assembly