19. Technical Data
Technical data provided are based on the air conditioner running under free frequency.
19.1 Cool Mode Performance Data
Unit setting: Standard piping length, Hi Fan, Cool mode at 16°C
Voltage: 230V
19.1.1 CS-HZ9RKE-1 / CU-HZ9RKE-1 CS-HZ9RKE-5 / CU-HZ9RKE-5
CS-AZ9RKE-1 / CU-AZ9RKE-1
Indoor (°C)
Outdoor DB (°C)
DB
WB
16
25
35
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
27
19.0
2990
2659
254
2810
2528
345
2500
2400
455
22.0
3337
2012
240
3095
1916
338
2719
1756
450
23
15.7
2840
2583
266
2629
2488
352
2343
2296
454
18.4
3075
2050
258
2800
1902
347
2515
1779
454
20
13.3
2028
1987
153
1930
1892
254
1834
1798
399
15.8
2043
1742
141
2524
1844
349
2252
1724
452
(Dry bulb value based on 46% humidity)
19.1.2 CS-HZ12RKE-1 / CU-HZ12RKE-1
Indoor (°C)
Outdoor DB (°C)
DB
WB
16
25
35
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
27
19.0
4186
3331
463
3934
3168
630
3500
3007
830
22.0
4672
2522
438
4333
2400
616
3807
2200
821
23
15.7
3976
3237
485
3680
3118
641
3280
2968
828
18.4
4305
2569
471
3919
2384
633
3520
2229
828
20
13.3
2503
2288
209
2702
2657
464
2568
2542
728
15.8
2519
1923
197
3534
2310
636
3152
2160
824
(Dry bulb value based on 46% humidity)
TC - Total Cooling Capacity (kW)
SHC - Sensible Heat Capacity (kW)
IP
- Input Power (kW)