15
Model
Indoor
CS-HZ12RKE-1
Outdoor
CU-HZ12RKE-1
Drain Hose
Inner Diameter
mm
16.2
Length
mm
650
Indoor Heat
Exchanger
Fin Material
Aluminium (Pre Coat)
Fin Type
Slit Fin
Row × Stage × FPI
2 × 17 × 21
Size (W × H × L)
mm
636.5 × 357 × 25.4
Outdoor Heat
Exchanger
Fin Material
Aluminium
Fin Type
Corrugate Fin
Row × Stage × FPI
2 × 28 × 19
Size (W × H × L)
mm
36.4 × 588 × 856.3:827.7
Air Filter
Material
Polypropelene
Type
One-touch
Power Supply
Indoor / Outdoor
Power Supply Cord
A
Nil
Thermostat
Electronic Control
Protection Device
Electronic Control
Dry Bulb
Wet Bulb
Indoor
Operation
Range
Cooling
Maximum °C
32
23
Minimum °C
16
11
Heating
Maximum °C
30
–
Minimum °C
16
–
+8/15°C
HEAT
Maximum °C
15
–
Minimum °C
8
–
Outdoor
Operation
Range
Cooling
Maximum °C
43
26
Minimum °C
16
11
Heating
Maximum °C
24
18
Minimum °C
-20
–
+8/15°C
HEAT
Maximum °C
–
–
Minimum °C
-20
–
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3.
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C.
4.
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C.
5.
Specifications are subjected to change without prior notice for further improvement.
6.
Maximum heating capacity shown are the values based on powerful operation.
7.
If the EUROVENT Certified models can be operated under the “extra-low” temperature condition, -7°C DB and -8°C WB temperature with
rated voltage 230V shall be used.
8.
The annual consumption is calculated by multiplying the input power by an average of 500 hours per year in cooling mode.
9.
SEER and SCOP classification is at 230V only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating
season. Other fiche data indicates in an attached sheet.
Содержание CS-HZ9RKE-1
Страница 28: ...28 11 1 4 Receiver Printed Circuit Board CN RCV 11 1 5 Fuse Printed Circuit Board ACL501 ACN501 ACL502 ACN502 ...
Страница 117: ...117 18 1 1 4 To remove control board Figure 6 18 1 1 5 To remove cross flow fan and indoor fan motor Figure 7 ...
Страница 118: ...118 Figure 8 Figure 9 ...
Страница 119: ...119 Figure 10 ...