![Panasonic CS-HZ9RKE-1 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/panasonic/cs-hz9rke-1/cs-hz9rke-1_service-manual_3879144011.webp)
11
Model
Indoor
CS-HZ9RKE-1 CS-HZ9RKE-5 CS-AZ9RKE-1
Outdoor
CU-HZ9RKE-1 CU-HZ9RKE-5 CU-AZ9RKE-1
Indoor
F
an
Type
Cross-Flow Fan
Material
ASG33
Motor Type
DC / Transistor (8-poles)
Input Power
W
44.9
Output Power
W
40
Speed
QLo
Cool
rpm
570
Heat
rpm
630
Lo
Cool
rpm
670
Heat
rpm
720
Me
Cool
rpm
880
Heat
rpm
990
Hi
Cool
rpm
1090
Heat
rpm
1270
SHi
Cool
rpm
1150
Heat
rpm
1340
Outdoo
r Fa
n
Type
Propeller Fan
Material
PP
Motor Type
DC Motor (8-poles)
Input Power
W
–
Output Power
W
40
Speed
Hi
Cool
rpm
850
Heat
rpm
850
Moisture Removal
L/h (Pt/h)
1.5 (3.2)
Indoor Airflow
QLo
Cool
m
3
/min (ft
3
/min)
6.01 (212)
Heat
m
3
/min (ft
3
/min)
6.78 (239)
Lo
Cool
m
3
/min (ft
3
/min)
7.29 (257)
Heat
m
3
/min (ft
3
/min)
7.93 (280)
Me
Cool
m
3
/min (ft
3
/min)
9.99 (353)
Heat
m
3
/min (ft
3
/min)
11.41 (403)
Hi
Cool
m
3
/min (ft
3
/min)
12.30 (435)
Heat
m
3
/min (ft
3
/min)
15.00 (530)
SHi
Cool
m
3
/min (ft
3
/min)
13.46 (475)
Heat
m
3
/min (ft
3
/min)
15.91 (562)
Outdoor
Airflow
Hi
Cool
m
3
/min (ft
3
/min)
33.10 (1170)
Heat
m
3
/min (ft
3
/min)
34.00 (1200)
Refrigeration
Cycle
Control Device
Expansion Valve
Refrigerant Oil
cm
3
FW50S (450)
Refrigerant Type
g (oz)
R32, 1.12k (39.5)
F-Gas
GWP
675
CO2eq (ton)
(Precharged Amount /
Maximum Charged Amount
0.756 / 0.925
Dimension
Height(I/D / O/D)
mm (inch)
295 (11-5/8) / 622 (24-1/2)
Width (I/D / O/D)
mm (inch)
870 (34-9/32) / 824 (32-15/32)
Depth (I/D / O/D)
mm (inch)
255 (10-1/16) / 299 (11-25/32)
Weight
Net (I/D / O/D)
kg (lb)
10 (22) / 38 (84)
Piping
Pipe Diameter (Liquid / Gas)
mm (inch)
6.35 (1/4) / 9.52 (3/8)
Standard length
m (ft)
5.0 (16.4)
Length range (min – max)
m (ft)
3 (9.8) ~ 20 (65.6)
I/D & O/D Height different
m (ft)
10.0 (32.8)
Additional Gas Amount
g/m (oz/ft)
20 (0.2)
Length for Additional Gas
m (ft)
7.5 (24.6)