6
CARE & CLEANING
CARE & CLEANING
•
Switch off the power supply and unplug before cleaning.
•
Do not touch the aluminium
fi
n, sharp parts may cause injury.
Remove
Remove
WASHING INSTRUCTIONS
WASHING INSTRUCTIONS
• Do not use benzene, thinner or scouring powder.
• Use only soap ( pH7) or neutral household detergent.
• Do not use water hotter than 40°C.
HINTS
HINTS
• Clean the
fi
lter regularly for best performance and to
reduce power consumption.
• Please consult your nearest dealer for seasonal
inspection.
FOR SEASONAL INSPECTION AFTER EXTENDED
FOR SEASONAL INSPECTION AFTER EXTENDED
NON-USE
NON-USE
• Checking of remote control batteries.
• No obstruction at air inlet and air outlet vents.
• After 15 minutes of operation, it is normal to have the
following temperature difference between air inlet and air
outlet vents:
Cooling:
≥
8°C
Heating:
≥
14°C
NON SERVICEABLE CRITERIAS
NON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY AND UNPLUG then CALL
Authorized Distributor under the following conditions:
• Abnormal noise during operation.
• Water/foreign particles have entered the remote control.
• Water leaks from Indoor unit.
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
• Switches or buttons are not functioning properly.
FOR EXTENDED NON-USE
FOR EXTENDED NON-USE
• Activate heat mode for 2~3 hours to thoroughly dry the unit.
• Turn off the power supply and unplug.
• Remove the remote control batteries.
AIR FILTERS
AIR
FILTERS
• Air
fi
lters cleaning is needed every two weeks.
• Wash/rinse the
fi
lters gently with water to
avoid damage to the
fi
lter surface.
• Dry the
fi
lters thoroughly under the shade,
away from
fi
re or direct sunlight.
• Replace any damage
fi
lter.
Remove
Remove
CAUTION
FRONT PANEL
FRONT
PANEL
Raise and pull to remove.
Wash gently and dry.
INDOOR UNIT
INDOOR
UNIT
Wipe the unit gently with a
soft, dry cloth.
ALUMINIUM FIN
ALUMINIUM FIN
IONIZER
IONIZER
Clean with cotton bud.
SUPERSONIC AIR PURIFYING DEVICE
SUPERSONIC AIR PURIFYING DEVICE
• It is recommended to clean the
fi
lter every 6 months.
• Replace the
fi
lter every 3 years or replace any
damaged
fi
lter.
Part no.: CZ-SA13P
Vacuum the super
alleru-buster
fi
lter.
Remove
Vacuum, wash
and dry the frame.
Содержание CS-E9HKEA
Страница 44: ...44 ELCB EarthLeakageCircuitBreaker RCD ResidualCurrentDevice Ni Cd...
Страница 45: ...45 E 44 45 46 47 48 49 C DBT WBT DBT WBT 32 23 43 26 16 11 15 30 24 18 16 10 DBT WBT 15 C 16 C 80 15 C 15 C GB...
Страница 48: ...48 6 3 CZ SA13P super alleru buster pH7 40 C 15 8 C 14 C 2 3...
Страница 49: ...49 E TIMER ON SET OFF AC RC RESET SET CHECK CLOCK 1 3 2 CANCEL 1 5 3 2 4 ION ON...
Страница 50: ...50 ELCB RCD Ni Cd...
Страница 51: ...51 50 51 52 53 54 55 C DBT WBT DBT WBT 32 23 43 26 16 11 15 30 24 18 16 10 DBT WBT 15 C 16 C 80 15 C 15 C...
Страница 54: ...54 6 3 CZ SA13P pH7 40 C 15 8 C 14 C 2 3...
Страница 55: ...55 TIMER ON SET OFF AC RC RESET SET CHECK CLOCK 1 3 2 CANCEL 1 5 3 5 2 4 ION ON...