![Panasonic CS-E24DKE Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/panasonic/cs-e24dke/cs-e24dke_service-manual_256896015.webp)
Table (b): Outdoor Air Temperature Shifting
Mode:
Outdoor Temperature, X (°C):
Temperature Shift (°C)
Manual Operation
Auto Operation
Cooling/Soft Dry
38
X
1.50
2.00
30
X
38
1.25
1.25
23
X
30
1.25
1.25
X
23
1.75
1.75
Heating
21
X
-2.25
-1.50
17
X
21
-1.75
-1.00
13
X
17
-0.75
0.00
9
X
13
0.25
0.25
5
X
9
1.25
1.00
1
X
5
0.75
1.00
-3
X
1
1.50
1.00
X
-3
1.50
1.00
Table (c): Powerful Mode Shifting
Mode:
Period, X (min):
Temperature Shift (°C)
Cooling
X
20
-2.0
X
20
0.0
Soft Dry
X
20
-1.0
X
20
0.0
Heating
X
20
+3.5
X
20
+3.5
Table (d): Fan Speed Shifting
Mode:
Fan Speed:
Temperature Shift (°C)
Cooling
All
-0.25
Soft Dry
All
+0.0
Heating
Lo
+2.0
Me-, Me, Me+, Auto, Hi
+1.5
Table (e): Start-Up Shifting
Mode within 60 Minutes from Start-up:
Temperature Shift (°C)
Cooling/Soft Dry
-1.0
Heating
+2.0
15
CS-E24DKE CU-E24DKE
Содержание CS-E24DKE
Страница 9: ...4 Dimensions 4 1 Indoor Unit Remote Control 9 CS E24DKE CU E24DKE ...
Страница 10: ...4 2 Outdoor Unit 10 CS E24DKE CU E24DKE ...
Страница 11: ...5 Refrigeration Cycle Diagram 11 CS E24DKE CU E24DKE ...
Страница 12: ...6 Block Diagram 12 CS E24DKE CU E24DKE ...
Страница 13: ...7 Wiring Diagram 13 CS E24DKE CU E24DKE ...
Страница 19: ...B Indoor Fan Control i Indoor fan control operation outline 1 Cooling Dry 2 Heating 19 CS E24DKE CU E24DKE ...
Страница 62: ...3 For the embedded piping This can be used for left rear piping left bottom piping also 62 CS E24DKE CU E24DKE ...
Страница 77: ...13 Technical Data 77 CS E24DKE CU E24DKE ...
Страница 89: ...89 CS E24DKE CU E24DKE ...
Страница 91: ...18 3 Remote Control 91 CS E24DKE CU E24DKE ...
Страница 92: ...18 4 Print Pattern Indoor Unit Printed Circuit Board 92 CS E24DKE CU E24DKE ...
Страница 93: ...18 5 Print Pattern Outdoor Unit Printed Circuit Board 93 CS E24DKE CU E24DKE PHAAM Printed in Malaysia ...
Страница 94: ......