Remote control

Do not allow infants and small children to play 
with the remote control to prevent them from 
accidentally swallowing the batteries.

Power supply

Do not use a modified cord, 
joint cord, extension cord or 
unspecified cord to prevent 
overheating and fire.

  

To prevent overheating, fire or electric shock:
• Do not share the same power outlet with 

other equipment.

• Do not operate with wet hands. 
• Do not over bend the power supply cord.
• Do not operate or stop the unit by inserting 

or pulling out the power plug.

If the supply cord is damaged, it must be 
replaced by the manufacturer, service agent 
or similarly qualified persons in order to avoid 
a hazard.
It is strongly recommended to be installed 
with Earth Leakage Circuit Breaker (ELCB) 
or Residual Current Device (RCD) to prevent 
electric shock or fire.
To prevent overheating, fire or electric shock:
• Insert the power plug properly.
• Dust on the power plug should be 

periodically wiped with a dry cloth.

Stop using the product if any abnormality/
failure occurs and disconnect the power plug 
or turn off the power switch and breaker.
(Risk of smoke/fire/electric shock) Examples 
of abnormality/failure
• The ELCB trips frequently.
• Burning smell is observed.
• Abnormal noise or vibration of the unit is 

observed.

• Water leaks from the indoor unit.
• Power cord or plug becomes abnormally hot.
• Fan speed cannot be controlled.
• The unit stops running immediately even if it 

is switched on for operation.

• The fan does not stop even if the operation 

is stopped.

Contact your local dealer immediately for 
maintenance/repair.

This equipment must be earthed to prevent 
electrical shock or fire.

Prevent electric shock by switching off the 
power supply and unplug:
- Before cleaning or servicing,
- When extended non-use, or
- During abnormally strong lightning activity.

Precaution for using R32 refrigerant

The basic installation work procedures are the same as 
conventional refrigerant (R410A, R22) models.

Since the working pressure is higher than that of 
refrigerant R22 models, some of the piping and 
installation and service tools are special.
Especially, when replacing a refrigerant R22 
model with a new refrigerant R32 model, always 
replace the conventional piping and flare nuts 
with the R32 and R410A piping and flare nuts on 
the outdoor unit side.
For R32 and R410A, the same flare nut on the 
outdoor unit side and pipe can be used.
Models that use refrigerant R32 and R410A 
have a different charging port thread diameter to 
prevent erroneous charging with refrigerant R22 
and for safety.
Therefore, check beforehand. [The charging port 
thread diameter for R32 and R410A is 1/2 inch.]
Be more careful than R22 so that foreign matter 
(oil, water, etc.) does not enter the piping.
Also, when storing the piping, securely seal the 
opening by pinching, taping, etc. (Handling of 
R32 is similar to R410A.)

CAUTION

Indoor unit and outdoor unit

Do not wash the indoor unit with water, benzine, 
thinner or scouring powder to avoid damage or 
corrosion at the unit.
Do not use for preservation of precise 
equipment, food, animals, plants, artwork 
or other objects. This may cause quality 
deterioration, etc.
Do not use any combustible equipment in front 
of the airflow outlet to avoid fire propagation.
Do not expose plants or pet directly to airflow to 
avoid injury, etc.

Do not touch the sharp aluminium fin, 
sharp parts may cause injury.

Do not switch ON the indoor unit when waxing 
the floor. After waxing, aerate the room properly 
before operating the unit.
Do not install the unit in oily and smoky areas to 
prevent damage to the unit.
Do not dismantle the unit for cleaning purpose 
to avoid injury.
Do not step onto an unstable bench when 
cleaning the unit to avoid injury.
Do not place a vase or water container on the 
unit. Water may enter the unit and degrade the 
insulation. This may cause an electric shock.
Do not open window or door for long time during 
operation, it may lead to inefficient power usage 
and uncomfortable temperature changes.

5

Содержание CS/CU-HU12AKY Series

Страница 1: ...then request the customer keep them for future reference Remove the remote control packed with the indoor unit Air conditioner Operating Installation Instructions Images are for Illustration purpose o...

Страница 2: ...INVERTER leverages ECONAVI sensor data and varies compressor rotation speed This helps to optimize cooling operation and reduces wasteful cooling nanoe G nanoeX Purifies the air down to the smallest p...

Страница 3: ...y FAN DRY 2 1 3 7m Accessories Remote control AAA or R03 batteries 2 Remote control holder Screws for remote control holder 2 Ag Clean PM 0 1 Filter Safety precautions 4 9 How to use 10 11 To learn mo...

Страница 4: ...e internal parts repair install remove and reinstall the unit Improper installation and handling will cause leakage electric shock or fire Confirm with authorised dealer or specialist on usage of any...

Страница 5: ...the same as conventional refrigerant R410A R22 models Since the working pressure is higher than that of refrigerant R22 models some of the piping and installation and service tools are special Especi...

Страница 6: ...accredited assessment authority which authorizes their competence to handle refrigerants safely in accordance with an industry recognised assessment specification Servicing shall only be performed as...

Страница 7: ...where they are unlikely to be exposed to any substance which may corrode refrigerant containing components unless the components are constructed of materials which are inherently resistant to being co...

Страница 8: ...nd during the brazing process 8 Removal and evacuation When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However it is important...

Страница 9: ...hat it has been de commissioned and emptied of refrigerant The label shall be dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 12 Rec...

Страница 10: ...AU18AKYF Model FAN To operate Air Con in Fan Only mode Indoor unit temp display will show set temp for AUTO COOL DRY mode and room temp for FAN mode Only indoor unit fan operates as per remote setting...

Страница 11: ...operation stops automatically after 1 hour JETSTREAM To set the timer To turn ON and OFF the unit at a preset time To enjoy freshness and cleaner environment This is a combination operation together...

Страница 12: ...g low activity to maximise energy saving Mode Human Low activity COOL Set temperature ECONAVI take advantage of the human nature that human being takes time to feel the temperature rise during low act...

Страница 13: ...native to remove moisture left in the internal parts thoroughly to prevent mould growth Turn off the power supply and unplug Remove the remote control batteries nanoe G Generator For better efficiency...

Страница 14: ...and some alpha numeric codes appear on IDU display Unit s Wi Fi connection with the router is activated Wi Fi LED stays ON during unit turn OFF Check unit s Wi Fi connection with router Wi Fi LED coun...

Страница 15: ...Note 15 English Troubleshooting...

Страница 16: ...condenser is not obstructed There should not be any animal or plant which could be affected by hot air discharged Keep the spaces indicated by arrows from wall ceiling fence or other obstacles Do not...

Страница 17: ...checking for gas leaks and secure with vinyl tape Vinyl tape Insulation of piping connections Remote control holder Remote control holder fixing screws Remote control Attaching the remote control hold...

Страница 18: ...ount the installation plate on the wall with 5 screws or more at least 5 screws If mounting the unit on the concrete wall consider using anchor bolts Always mount the installation plate horizontally b...

Страница 19: ...left piping Right Rear piping Cover for piping How to keep the cover In case of the cover is cut keep the cover at the rear of chassis as shown in the illustration for future reinstallation Left right...

Страница 20: ...ction cable Gas side piping Liquid side piping Drain hose Insert the connection cable This can be used for left rear piping and bottom piping also How to pull the piping and drain hose out in case of...

Страница 21: ...oprene sheathed 4 x 1 0 mm2 1 5 1 8HP 4 x 1 5 mm2 2 0HP or 4 x 2 5mm2 2 5HP flexible cord type designation IS 694 or 60245 IEC 57 or heavier cord Bind all the indoor and outdoor connection cable with...

Страница 22: ...n this area must follow to national wiring rules Do not joint wires Wire stripping No loose strand when inserted 10 1 mm Conductor fully inserted ACCEPT Conductor over inserted PROHIBITED Conductor no...

Страница 23: ...orque wrench Spanner or Wrench Decide piping length and then cut by using pipe cutter Remove burrs from cut edge Make flare after inserting the flare nut locate at valve onto the copper pipe Align cen...

Страница 24: ...unit and outdoor unit shall be approved polychloroprene sheathed 4 x 1 0 mm2 1 5 1 8HP 4 x 1 5 mm2 2 0HP or 4 x 2 5mm2 2 5HP flexible cord type designation IS 694 or 60245 IEC 57 or heavier cord Do n...

Страница 25: ...as shown in the illustration 3 Then remove the 2 1 5HP or 4 2 0 2 5HP mounting screws 4 Pull the lower section of the front grille towards you to remove the front grille The below operations will be p...

Страница 26: ...aterial with a new one Heat insulating material is required for both liquid side and gas side piping Most Important Process Purpose To make the oil refrigerant mix together They are in separated condi...

Страница 27: ...or dwelling or room must be made by brazing orwelding Joint connection of indoor unit by flaring method can only be made at outdoor or at outside of a buidling or dwelling or room Flare connection ma...

Страница 28: ...b 17 C for Half Load 50 For Full Load QUIET CLEAN Open the Front Panel by lifting Intake Grille Follow the below Instructions 4 Air Swing Horizontal Airflow Set vane position to be AUTO 5 Fan speed M...

Страница 29: ...door Unit Control button while holding the indoor unit button Step b Within 5 second press once the Remote Step c After hearing a beep sound from the Indoor Unit immediately release the Auto OFF ON bu...

Страница 30: ...ed above carries warranty for 3 years from the date of purchase Product ROOM AIR CONDITIONER Panasonic Life Solutions India Pvt Ltd Model No ODU SI No IDU SI No Customer Name Address Tel No Date of Pu...

Страница 31: ...ject or living creature eg Rat lizard insect ants etc inside the Product unit f Use of harmful chemicals Improper heat load Usage of unit in an abnormally corrosive alkaline acidic atmosphere g Any ch...

Страница 32: ...m in corporate sustainability panasonic india i recycle program html S No 1 All electrical and electronic products are required to be handed over only to the Authorized recycler 2 The product should b...

Отзывы: