Panasonic CS/CU-HU12AKY Series Скачать руководство пользователя страница 10

MODE

SMART

1
2

1
2

FAN SPEED

JET STREAM

ON

POWERFUL

MODE

TEMP

SWING

DISPLAY

CANCEL

CLEAN

ECONAVI

nanoe

CLOCK/

LOCK

RESET

RC

AC

CHECK

SET

SLEEP

SMART

SWING

OFF

AIR CONDITIONER

converti7

How to use

Auto OFF/ON button

Use when remote control is misplaced or a malfunction occurs. Raise the front panel:
• Press the button to switch ON the unit.  
• Press the button again to turn OFF.

Remote control 
display

Remote control

receiver and indicator 

ECONAVI 

nanoe

ECONAVI

Wi-Fi

nanoe

Wi-Fi

TIMER

10

SLEEP

To maximise comfort while 

sleeping

• This operation provides you with a comfortable
  environment while sleeping by gradually increase
  the set temperature 1 °C after every 3 hours operation.
• The unit is turned off after 8 hours.
• Can be cancelled by pressing the respective
  button again. 

SLEEP: Display on remote LCD

To select operation mode

AUTO - For your convenience 

COOL - To enjoy cool air 

DRY - To dehumidify the environment

• During operation, based on Set and Room temp.
  operation mode will be judged and IDU fan motor
  will be OFF during this period.

• To reduce power consumption during COOL mode, 
  use curtains to screen off sunlight and outdoor heat.

• Unit operates at Low fan speed to give a gentle
  cooling operation.

*Vertical flaps will not work in AUTO air swing in HU and 
  AU18AKYF Model.

FAN - To operate Air-Con in “Fan Only” mode

* Indoor unit temp. display will show set temp. for 
  AUTO,COOL & DRY mode and room temp. for FAN 
  mode.

• Only indoor unit fan operates as per remote settings.
• Outdoor is OFF, so no cooling achieved.
• Provides air circulation in the room.

MODE

Press for “5” seconds to

lock / unlock remote keypad.

When keypad is locked, remote

display will show ‘LOCK’ when 

any button is pressed or press

to set clock.

Not used in normal

operations.

Long Press to restore the 

remote control to default setting.

‘CL’ will be displayed on unit and remote controller.
While ‘CL’ is displayed, all other functions of the
remote controller will be disabled, except for
ON/OFF button. 

Applicable for 10 to 15 minutes.

This feature can only be used in OFF condition.

CLEAN

To clean dust on Evap. Coil of
the Air-Conditioner Unit

To OFF/ON hidden temperature
display

• When the display is turned OFF by remote controller,
  It will turn ON automatically for few seconds upon
  receiving any command from remote or in case of
  mains power reset. 

DISPLAY

To turn ON/OFF Wi-Fi function 
of Air-Conditioner Unit.

SMART

Wi-Fi

Press            button for one time to switch ON Wi-Fi.
Press & hold            button for “5” seconds to enter
in setup mode.
Press            followed by CANCEL button to turn
OFF Wi-Fi for “4” hours.
Press & hold CANCEL button for “10” seconds to
check Wi-Fi connection.  

SMART

SMART

SMART

(For XU Series)

(For AU Series)

Wi-Fi

TIMER

(For HU Series)

Wi-Fi

(For AU18AKYF)

Applicable for AU Series

Содержание CS/CU-HU12AKY Series

Страница 1: ...then request the customer keep them for future reference Remove the remote control packed with the indoor unit Air conditioner Operating Installation Instructions Images are for Illustration purpose o...

Страница 2: ...INVERTER leverages ECONAVI sensor data and varies compressor rotation speed This helps to optimize cooling operation and reduces wasteful cooling nanoe G nanoeX Purifies the air down to the smallest p...

Страница 3: ...y FAN DRY 2 1 3 7m Accessories Remote control AAA or R03 batteries 2 Remote control holder Screws for remote control holder 2 Ag Clean PM 0 1 Filter Safety precautions 4 9 How to use 10 11 To learn mo...

Страница 4: ...e internal parts repair install remove and reinstall the unit Improper installation and handling will cause leakage electric shock or fire Confirm with authorised dealer or specialist on usage of any...

Страница 5: ...the same as conventional refrigerant R410A R22 models Since the working pressure is higher than that of refrigerant R22 models some of the piping and installation and service tools are special Especi...

Страница 6: ...accredited assessment authority which authorizes their competence to handle refrigerants safely in accordance with an industry recognised assessment specification Servicing shall only be performed as...

Страница 7: ...where they are unlikely to be exposed to any substance which may corrode refrigerant containing components unless the components are constructed of materials which are inherently resistant to being co...

Страница 8: ...nd during the brazing process 8 Removal and evacuation When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However it is important...

Страница 9: ...hat it has been de commissioned and emptied of refrigerant The label shall be dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 12 Rec...

Страница 10: ...AU18AKYF Model FAN To operate Air Con in Fan Only mode Indoor unit temp display will show set temp for AUTO COOL DRY mode and room temp for FAN mode Only indoor unit fan operates as per remote setting...

Страница 11: ...operation stops automatically after 1 hour JETSTREAM To set the timer To turn ON and OFF the unit at a preset time To enjoy freshness and cleaner environment This is a combination operation together...

Страница 12: ...g low activity to maximise energy saving Mode Human Low activity COOL Set temperature ECONAVI take advantage of the human nature that human being takes time to feel the temperature rise during low act...

Страница 13: ...native to remove moisture left in the internal parts thoroughly to prevent mould growth Turn off the power supply and unplug Remove the remote control batteries nanoe G Generator For better efficiency...

Страница 14: ...and some alpha numeric codes appear on IDU display Unit s Wi Fi connection with the router is activated Wi Fi LED stays ON during unit turn OFF Check unit s Wi Fi connection with router Wi Fi LED coun...

Страница 15: ...Note 15 English Troubleshooting...

Страница 16: ...condenser is not obstructed There should not be any animal or plant which could be affected by hot air discharged Keep the spaces indicated by arrows from wall ceiling fence or other obstacles Do not...

Страница 17: ...checking for gas leaks and secure with vinyl tape Vinyl tape Insulation of piping connections Remote control holder Remote control holder fixing screws Remote control Attaching the remote control hold...

Страница 18: ...ount the installation plate on the wall with 5 screws or more at least 5 screws If mounting the unit on the concrete wall consider using anchor bolts Always mount the installation plate horizontally b...

Страница 19: ...left piping Right Rear piping Cover for piping How to keep the cover In case of the cover is cut keep the cover at the rear of chassis as shown in the illustration for future reinstallation Left right...

Страница 20: ...ction cable Gas side piping Liquid side piping Drain hose Insert the connection cable This can be used for left rear piping and bottom piping also How to pull the piping and drain hose out in case of...

Страница 21: ...oprene sheathed 4 x 1 0 mm2 1 5 1 8HP 4 x 1 5 mm2 2 0HP or 4 x 2 5mm2 2 5HP flexible cord type designation IS 694 or 60245 IEC 57 or heavier cord Bind all the indoor and outdoor connection cable with...

Страница 22: ...n this area must follow to national wiring rules Do not joint wires Wire stripping No loose strand when inserted 10 1 mm Conductor fully inserted ACCEPT Conductor over inserted PROHIBITED Conductor no...

Страница 23: ...orque wrench Spanner or Wrench Decide piping length and then cut by using pipe cutter Remove burrs from cut edge Make flare after inserting the flare nut locate at valve onto the copper pipe Align cen...

Страница 24: ...unit and outdoor unit shall be approved polychloroprene sheathed 4 x 1 0 mm2 1 5 1 8HP 4 x 1 5 mm2 2 0HP or 4 x 2 5mm2 2 5HP flexible cord type designation IS 694 or 60245 IEC 57 or heavier cord Do n...

Страница 25: ...as shown in the illustration 3 Then remove the 2 1 5HP or 4 2 0 2 5HP mounting screws 4 Pull the lower section of the front grille towards you to remove the front grille The below operations will be p...

Страница 26: ...aterial with a new one Heat insulating material is required for both liquid side and gas side piping Most Important Process Purpose To make the oil refrigerant mix together They are in separated condi...

Страница 27: ...or dwelling or room must be made by brazing orwelding Joint connection of indoor unit by flaring method can only be made at outdoor or at outside of a buidling or dwelling or room Flare connection ma...

Страница 28: ...b 17 C for Half Load 50 For Full Load QUIET CLEAN Open the Front Panel by lifting Intake Grille Follow the below Instructions 4 Air Swing Horizontal Airflow Set vane position to be AUTO 5 Fan speed M...

Страница 29: ...door Unit Control button while holding the indoor unit button Step b Within 5 second press once the Remote Step c After hearing a beep sound from the Indoor Unit immediately release the Auto OFF ON bu...

Страница 30: ...ed above carries warranty for 3 years from the date of purchase Product ROOM AIR CONDITIONER Panasonic Life Solutions India Pvt Ltd Model No ODU SI No IDU SI No Customer Name Address Tel No Date of Pu...

Страница 31: ...ject or living creature eg Rat lizard insect ants etc inside the Product unit f Use of harmful chemicals Improper heat load Usage of unit in an abnormally corrosive alkaline acidic atmosphere g Any ch...

Страница 32: ...m in corporate sustainability panasonic india i recycle program html S No 1 All electrical and electronic products are required to be handed over only to the Authorized recycler 2 The product should b...

Отзывы: