109
List of Error Codes
When turning on the computer, if one of the following error codes or messages is displayed,
follow the instructions shown below.
If the problem persists, or if the error code or message displayed is not shown here, contact
your technical support office.
Error Code/Message
Action
0212: Keyboard error
z
If an external keyboard is connected, disconnect this
device.
0251: System CMOS checksum
bad - Default configuration used
An error has occurred in the memory that stores the
Setup Utility settings. This error occurs when the
memory content is changed through some inadvertent
operation by a program or other function.
z
Run the Setup Utility and load the default values,
then change the settings to the appropriate values as
needed. (
)
z
If the problem persists, the internal clock battery may
need to be replaced. Contact your technical support
office.
0271: Check date and time
settings
The date and time setting are incorrect.
z
Run the Setup Utility and set the date and time
correctly. (
)
z
If the problem persists, the internal clock battery may
need to be replaced. Contact your technical support
office.
0280: Previous boot incomplete -
Default configuration used
Startup has failed repeatedly, so the Setup Utility
settings have been returned to their default values, and
the computer has been booted.
z
Run the Setup Utility and load the default values,
then change the settings to the appropriate values as
needed. (
)
02B0: Diskette drive A error
z
Disconnect the floppy disk drive and reconnect it.
Make sure the drive is secured correctly.
Press <F1> to resume, <F2> to
Setup
z
Write down the error details and press
F2
to run the
Setup Utility. Confirm the settings, and change the
settings to the appropriate values as needed.
(