16
Connections
O
Use the AW-PS505 (optional accessory) for the main
unit’s AC adapter and the AW-PS300 (optional
accessory) for the pan-tilt head’s AC adapter.
O
Connect the DC 12V IN socket on the control panel with
the CONTROL PANEL POWER OUT connector on the
main unit, and the CONTROL OUT connector on the
control panel with the CONTROL IN TO CONTROL
PANEL connector 1 on the main unit using the cables (10
m) supplied.
To extend the connection distance between the control
panel and main unit beyond 10 meters, the AW-PS505
(optional accessory) as the power supply for the control
panel and a 10BaseT straight cable (for the control
signals) must be provided separately.
The maximum extension distance is 500 meters when the
10BaseT straight cable (equivalent to UTP category 5) is
used.
O
Use a DC power cable (which has a nominal cross-
sectional area of at least 1.25 mm
2
and which complies
with the Electrical Appliance and Material Control Law) to
connect the AW-PH350 pan-tilt head and AW-PS300
pan-tilt head AC adapter.
The maximum extension distance between the AC
adapter for the pan-tilt head and the pan-tilt head itself is
30 meters.
O
Connect the AW-PH350 pan-tilt head and convertible
camera using the composite camera cable (AW-
CA50T29) or component camera cable (AW-CA50C29).
O
Connect the iris control cable of the motorized zoom lens
to the camera and the remote (zoom/focus control) cable
to the pan-tilt head.
When using composite signals
O
The AW-CA50T29 (optional accessory) is required to
connect the convertible camera to the AW-PH350 pan-tilt
head.
O
To connect the main unit and pan-tilt heads, use two
coaxial cables (one for the video signals and the other for
the G/L signals) and one 10BaseT straight cable (for the
camera/pan-tilt head control signals) for each pan-tilt
head.
The maximum extension distance is 1,000 meters for
each pan-tilt head (when coaxial cables equivalent to
BELDEN 8281 and a 10BaseT straight cable equivalent
to UTP category 5 are used).
When using component signals
O
The AW-CA50C29 (optional accessory) is required to
connect the convertible camera to the AW-PH350 pan-tilt
head.
O
To connect the main unit and pan-tilt heads, use four
coaxial cables (one each for the Y signals, Pr signals, Pb
signals and G/L signals) and one 10BaseT straight cable
(for the camera/pan-tilt head control signals) for each
pan-tilt head.
The maximum extension distance is 1,000 meters for
each pan-tilt head (when coaxial cables equivalent to
BELDEN 8281 and a 10BaseT straight cable equivalent
to UTP category 5 are used).
O
When component signals are used, the RGB card (AW-
PB302) available as an optional accessory must be
installed in the convertible camera.
Turn off the power of all components before
proceeding with the connections.
For further details on how to connect each component,
refer to the operating instructions of the component
concerned.
Содержание AWRP605 - CCU & PAN/TILT CONTR
Страница 45: ......
Страница 91: ......
Страница 92: ...Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario L4W 2T3 905 624 5010 ...