28 (E)
ENGLISH
Operation (3D mode)
Enabling the keystone function
Press the [CONFIG] button to light its indicator, and
display the CONFIG menu.
Turn [F1] to display the Keystone sub menu.
<Menu display>
CONFIG 3|Keyston|Input |CH |
Keystone| Off| IN1| L|
On IN1
|
IN15
IN-A1
R
Turn [F2] to select On or Off for the Keyston item.
On:
The keystone function is enabled.
Off:
The keystone function is disabled.
Turn [F3] to select the input whose keystone function
will be enabled for the Input item.
Select an odd-numbered input connector.
The keystone function is applied to both the input of
this connector (Lch) and the input of the
even-numbered input connector (Rch) in the same
pair of connectors.
Turn [F4] to select the image to be adjusted for the CH
item.
L:
The input image (Lch) selected for the Input item is
adjusted.
R:
The input image (Rch) of the even-numbered
input connector in the same pair of connectors is
adjusted.
Moving the images and adjusting their size
Press the [CONFIG] button to light its indicator, and
display the CONFIG menu.
Turn [F1] to display the KystnPos sub menu.
<Menu display>
CONFIG 4|X-Pos |Y-Pos |Size |
KystnPos| 0.00| 0.00| 100.00|
−50.00
|
50.00
−50.00
|
50.00
0.00
|
120.00
Turn [F2], [F3] and [F4] to adjust the X coordinate,
Y coordinate and size of the image.
When [F2], [F3] and [F4] are turned clockwise:
The value changes in the “+” direction.
When [F2], [F3] and [F4] are turned
counterclockwise:
The value changes in the “–” direction.
These adjustments can also be performed by
operating the positioners (X coordinate and Y
coordinate) and rotary encoder [Z] (size).
Applying the rotation effects to the images
Press the [CONFIG] button to light its indicator, and
display the CONFIG menu.
Turn [F1] to display the KystnRot sub menu.
<Menu display>
CONFIG 5|X |Y |Z |
KystnRot| 0.00| 0.00| 0.00|
−360.00
|
360.00
−360.00
|
360.00
−360.00
|
360.00
Turn [F2], [F3] and [F4] to adjust the angle (X direction,
Y direction and Z axis) at which the image is to be
rotated.
When [F2], [F3] and [F4] are turned clockwise:
The value changes in the “+” direction.
When [F2], [F3] and [F4] are turned
counterclockwise:
The value changes in the “–” direction.
These adjustments can also be performed by
operating the positioners (X direction and Y direction)
and rotary encoder [Z] (Z axis).