Specifications
Power supply:
DC 12 V
(when external power is supplied)
AC 220 V
(when CCU is connected)
Power consumption: 28 W (during external power
supply operation, camera only)
70 W (when CCU is connected)
p
When CCU is connected, the unit operates within a range
of AC 150 V to 240 V.
indicates safety information.
Ambient temperature range:
–10 °C to 45 °C
[Preheating required at temperatures
below 0 °C]
Storage temperature range:
–20 °C to 60 °C
Operating ambient humidity:
Less than 85 %
Weight:
Approx. 4.7
kg
Dimensions:
135 mm
260 mm
360 mm
(W
H
D)
[excluding protrusions]
Basic items
1) Pickup device:
2/3-type 2.2 million pixel IT-CCD
3
2) System:
GBR pickup system
3) Colour separation optical system:
F1.4 prism
4) Optical filters:
CC: 3200K, 4300K, 6300K, Cross,
Diffusion
ND: CAP, Through, 1/4, 1/16, 1/64
5) Lens mount:
Bayonet type
6) Output standard: SMPTE 292M
7) Sensitivity:
F10 (When vertical frequency is 59.94 Hz)
F11 (When vertical frequency is 50 Hz),
2000 lx, 3200K,
white reflectance 89.9 %
8) Horizontal modulation:
More than 50 % (27.5 MHz)
9) S/N ratio:
60 dB typ. (Y: 30 MHz)
10) Horizontal frequency:
33.716 kHz, 1125-line frame
(Vertical frequency: 59.94 Hz)
28.125 kHz, 1125-line frame
(Vertical frequency: 50 Hz)
11) Vertical frequency:
59.94 Hz or 50 Hz, interlace
12) Output formats:
1080/59.94i, 1080/50i, 1080/29.97PsF,
1080/25PsF, 1080/23.98PsF over59.94i
Input/output signals
1) MIC input:
–60 dBu to +4 dBu
(XLR 3-pin female
2)
Gain selected by camera menu
2) INCOM:
Input: –60 dBu to –10 dBu
Output: 100 mW max
(XLR, 5-pin female
2)
(Mixing is controlled separately for
PGM1 and PGM2.)
3) HD-SDI1/HD-SDI2 output:
HD signal = 0.8 V [p-p], 75
(BNC)
The HD-SDI2 signal output can be
added to the regular images using the
camera menu item setting and switched
to the VF or RET image output.
With embedded audio signal (mute
when RET image output)
4) Prompt output:
VBS signal = 1 V [p-p], 75
(BNC)
G/L input:
Tri-level SYNC or black burst (BNC)
Selected using a switch.
5) AUX BNC
Prompt2 output: VBS signal = 1 V [p-p], 75
(BNC)
(When the CCU has a Prompt2 input)
6) DC OUT:
12 V, MAX. 1 A
Control
1) Power selection: CCU, OFF, EXT
2) USER 1, 2, 3:
Functions specified by menu items can
be allocated to the switch.
3) RET A/B selection:
For selecting the return signal
4) Monitor selection: Y/C, NAM, R, G, B
5) RET, PTT SW:
RET, PTT
6) Gain selection: LOW, MID, HIGH
7) Output selection: CAM, BAR, TEST
8) White balance mode:
A, B, preset
9) Shutter speed selection:
p
When the system format is [59.94i]
1/100, 1/120, 1/125, 1/250, 1/500, 1/1000, 1/1500,
1/2000
p
When the system format is [50i]
1/60, 1/100, 1/125, 1/250, 1/500, 1/1000, 1/1500,
1/2000
p
When the system format is any of [29.97PsF], [25PsF]
and [23.98PsF over59.94i]
1/48, 1/50, 1/60, 1/96, 1/100, 1/120, 1/250, 1/500