- 6 -
Usage Precautions
Standard on the safety of LED products
LED light source used in this product is the scope of application of “Photobiological Safety of Lamps and Lamp
Systems (JIS C7550:2011, IEC62471:2006).”
Standard
: JIS C7550:2011, IEC62471:2006
Classification
: Risk group 3
However, we recommend safety management equivalent to Class 4 under “Standard on the safety levels of laser
products” in consideration of safety for users.
<Reference: Standard on the safety levels of laser products>
Standard
: IEC60825-1 Edition2.0:2007
JIS C6802:2011
Classification : Class 4
Wavelength
: 365
±
10nm, 385
±
10nm
<Safety control items>
Do not see or catch on skin the direct or reflected light of LED while it’s on.
(It may cause disorders and inflammation in the eye or the skin.)
Set up the unit in such manner to avoid exposure of human body to LED-UV light.
(Exposure to LED-UV light may cause disorders and inflammation in the skin. If there is a risk of
exposure to LED-UV light and UV reflection, cover up with a shield with appropriate transmittance and
thermal characteristics to block the UV light.)
Be sure to wear protective glasses (UV light blocking) and protective gears when installing and operating.
(Failure to wear them may cause disorders and inflammation in the eye or the skin.)
*Handling of LED products overseas
Though LEDs are currently excluded from the application of “Standard on the safety of laser products” under
IEC and JIS as of current, older editions may be adopted in some countries and regions. Hence, please
check the laser safety regulations and standards of the country of usage.