- 19 -
1. Installation environment
1.Ambient temperature: 0 to +35
°
C, ambient humidity: 30 to 85%RH (at 25
°
C), no dewing or freezing
2.Must be a place free from dust, oil smoke, conductive dust, corrosive or flammable gas, salt content, and iron
dust.
3.Must be a place free from splashes of water, oil and chemicals.
4.Must be a place free from sudden temperature changes, vibration and shocks.
5.Must be a place free from direct sunlight.
6.Must be a place free from high magnetic field and intense electric field.
2. Work at your expense
1.Installation and wiring work with device at installation location
2.Power source to feed to device and related wiring work
• Primary power supply work
3.Works other than what is prescribed as work to be done at our expense on estimate sheet
3. Installation of device
[Control unit, power unit]
1.Place the rubber feet on a horizontal surface.
2.Do not install in tilted, sidelong, or flipped positions.
It may cause breakage due to occurrence of heating.
3.Do not install in a sealed space.
4.Do not block the ventilation hole of the power unit.
5.Please have a margin to installation space, and do not allow the exhaust air from the fan to enter through the air
intake.
6.Take external safety measures (interlocking, installation of smoke detector, etc.) so that a fail-safe mechanism
will work for the entire system in the case of product failures or errors caused by external factors.
[LED head]
1.Do not block the ventilation hole.
It may result in abnormal heating.
2.Do not touch the radiation window (glass) with bare hands.
It may cause taint.
3.UV radiation unit (radiation window) is protected by glass.
Impact to this area may cause breakage of glass.
Stains in this area may reduce UV output intensity.
Wipe taint, if any, with alcohol (ethanol, IPA) thoroughly.
4.See the LED head specification sheet for details needed for appropriate installation.