- 42 -
5) Operation of device
3. Input and output specifications
Input specifications
Inter
na
l
ci
rcui
t
24V
COM
INPUT
External emergency stop - 2 (No.18 pin)
External emergency stop - 1 (No.17 pin)
Open collector
Relay contact
Relay contact
Connection example
[Caution] Rated input voltage: 24V
Maximum input current: 10mA
[Caution] Dry contacts must be used for external
emergency stop.
Maximum rated voltage: 30V DC
Maximum rated amperage: 1A DC
UD40 controller side
Output specifications
COM
OUTPUT
Internal circuit
UD40 controller side
[Caution]
Output type
: Relay contact output
Maximum rated voltage
: 30V DC
Maximum rated amperage
: 1A DC