16.2 Performance Specifications of the Pulse Output Unit
■
Performance specifications
Item
Specifications
Product No.
AGM1PG04T
AGM1PG04L
Output type
Transistor
Line driver
Number of axes controlled
4 axis, independent
Position
command
Command unit
Pulse unit (for increment or absolute)
Max. pulse count Signed 32 bits (-2,147,483,648 to +2,147,483,647 pulses)
Speed command Command range
1 pps to 500 kpps
(can be set in 1 pps.)
1 pps to 4 Mpps
(can be set in 1 pps.)
Acceleration /
deceleration
command
Acceleration /
deceleration
method
Linear acceleration / deceleration, S-shaped acceleration / deceleration
control
S-shape pattern
Can be selected from Sine curve, Cubic curve.
Home return
Home return
speed
Speed setting possible (changes return speed and search speed)
Input signal
Home input, near home input, over limit input (+), over limit input (-)
Output signal
Deviation counter clear signal
Operation mode
● E-point control (Linear and S-shaped acceleration / deceleration)
● P-point control (Linear and S-shaped acceleration / deceleration)
● Home return (Home search)
● JOG positioning
● Pulser input operation
Transfer multiplication ratio (x1, x2, x5, x10, x50, x100, x500, x1000)
● Real-time frequency change function
Startup time
0.001 ms / 0.005 ms / 0.02 ms
Output interface
Output mode
Pulse / Sign, CW / CCW
Feedback
counter
function
Counting range
Signed 32 bits (-2,147,483,648 to +2,147,483,647 pulses)
Input mode
2-phase input, direction identification input, individual input (transfer
multiple available for each mode)
Max. counting
speed
4 MHz (2-phase input)
1 MHz (Direction distinction input and individual input)
Other functions
● Built-in over limit input (+) and over limit input (-)
● Servo ON output incorporated
(Note 1)
When Linear acceleration/deceleration operation is selected, the target speed can be changed during
an operation.
(Note 2)
"Pulser input operation" and "Feedback counter" use the same pulse input terminal. Either function of
the two can only be used.
16.2 Performance Specifications of the Pulse Output Unit
WUME-GM1PG-01
16-3
Содержание AGM1PG04L
Страница 2: ... MEMO 2 WUME GM1PG 01 ...
Страница 11: ...1 Before Using This Product 1 1 Safety Precautions 1 2 1 2 Handling Precautions 1 3 WUME GM1PG 01 1 1 ...
Страница 14: ... MEMO 1 4 WUME GM1PG 01 ...
Страница 22: ... MEMO 2 8 WUME GM1PG 01 ...
Страница 42: ... MEMO 3 20 WUME GM1PG 01 ...
Страница 52: ...4 5 Increment and Absolute 4 10 WUME GM1PG 01 ...
Страница 70: ...AccDec 10000 END_CASE 6 1 Sample Program 6 6 WUME GM1PG 01 ...
Страница 82: ... MEMO 7 10 WUME GM1PG 01 ...
Страница 90: ... MEMO 8 8 WUME GM1PG 01 ...
Страница 94: ...AccDec 10000 END_CASE 9 1 Sample Program 9 4 WUME GM1PG 01 ...
Страница 108: ...Current stops when the home or near home position is detected 10 4 Home and Near Home Input Logic 10 12 WUME GM1PG 01 ...
Страница 116: ... MEMO 10 20 WUME GM1PG 01 ...
Страница 124: ... MEMO 11 8 WUME GM1PG 01 ...
Страница 142: ... MEMO 14 4 WUME GM1PG 01 ...
Страница 158: ...16 3 Dimensions 16 3 1 Pulse Output Unit Unit mm 16 3 Dimensions 16 8 WUME GM1PG 01 ...
Страница 162: ... MEMO App 4 WUME GM1PG 01 ...
Страница 163: ...Record of Changes Date Manual No Record of changes August 2021 WUME GM1PG 01 1st edition WUME GM1PG 01 ...
Страница 164: ... MEMO WUME GM1PG 01 ...
Страница 165: ... MEMO WUME GM1PG 01 ...
Страница 166: ...Panasonic Corporation 2021 August 2021 WUME GM1PG 01 ...