Pin No.
Circuit
Signal name
Output specifications
Axis
1 / 3
Axis
2 / 4
Item
Description
B7
B16
COM
ON state max.
voltage drop
1.0 V
(Note 1)
The deviation counter clear signal is output when the power supply is turned ON for about 1 ms. When
the home return is complete, the signal is output for about 1 ms or 10 ms. The time can be specified
using the "Parameter".
Power supply terminal (common)
Pin No.
Circuit
Signal name
Power supply specifications
Item
Description
A20
External power supply
input:
24 V DC (+)
Supplied power
supply range
21.4 to 26.4 V DC
B20
External power supply
input:
24 V DC (-)
Consumption current
90 mA or less
(Note 1)
The external power supply input terminals between two connectors are connected internally.
Input terminals (common)
Pin No.
Circuit
Signal name
Input specifications
Axis
1 / 3
Axis
2 / 4
Item
Description
A3
A12
Home input
24 V DC (+)
(Z24)
Operating voltage
range
21.6 to 26.4 V DC
Min. ON voltage /
current
19.2 V DC / 5.5 mA
Max. OFF voltage/
current
2 V DC / 2 mA
Input impedance
Approx. 3.9 kΩ
Pulse width
100 μs or more
A4
A13
Home input
5 V DC (+)
(Z5)
Operating voltage
range
3.5 to 5.25 V DC
(5 V DC, Line driver
specifications)
Min. ON voltage /
current
3 V DC / 4 mA
Max. OFF voltage/
current
1 V DC / 0.5 mA
Input impedance
Approx. 560 Ω
Pulse width
100 μs or more
B3
B12
Home input (-)
-
-
16.2 Performance Specifications of the Pulse Output Unit
WUME-GM1PG-01
16-5
Содержание AGM1PG04L
Страница 2: ... MEMO 2 WUME GM1PG 01 ...
Страница 11: ...1 Before Using This Product 1 1 Safety Precautions 1 2 1 2 Handling Precautions 1 3 WUME GM1PG 01 1 1 ...
Страница 14: ... MEMO 1 4 WUME GM1PG 01 ...
Страница 22: ... MEMO 2 8 WUME GM1PG 01 ...
Страница 42: ... MEMO 3 20 WUME GM1PG 01 ...
Страница 52: ...4 5 Increment and Absolute 4 10 WUME GM1PG 01 ...
Страница 70: ...AccDec 10000 END_CASE 6 1 Sample Program 6 6 WUME GM1PG 01 ...
Страница 82: ... MEMO 7 10 WUME GM1PG 01 ...
Страница 90: ... MEMO 8 8 WUME GM1PG 01 ...
Страница 94: ...AccDec 10000 END_CASE 9 1 Sample Program 9 4 WUME GM1PG 01 ...
Страница 108: ...Current stops when the home or near home position is detected 10 4 Home and Near Home Input Logic 10 12 WUME GM1PG 01 ...
Страница 116: ... MEMO 10 20 WUME GM1PG 01 ...
Страница 124: ... MEMO 11 8 WUME GM1PG 01 ...
Страница 142: ... MEMO 14 4 WUME GM1PG 01 ...
Страница 158: ...16 3 Dimensions 16 3 1 Pulse Output Unit Unit mm 16 3 Dimensions 16 8 WUME GM1PG 01 ...
Страница 162: ... MEMO App 4 WUME GM1PG 01 ...
Страница 163: ...Record of Changes Date Manual No Record of changes August 2021 WUME GM1PG 01 1st edition WUME GM1PG 01 ...
Страница 164: ... MEMO WUME GM1PG 01 ...
Страница 165: ... MEMO WUME GM1PG 01 ...
Страница 166: ...Panasonic Corporation 2021 August 2021 WUME GM1PG 01 ...