background image

9

ROBATA 72/54 CONCRETE FIRE | Installation & Owner’s Manual

APPROVED FLEXIBLE GAS HOSE

A.G.A DESIGN-CERTIFIED MANUAL 

SHUTOFF VALVE WITH 1/8” NPT TAP

3” MINIMUM

CAP PIPE NIPPLE TEE JOINT

FROM GAS METER (5” W.C. 

TO 10.5” W.C. PRESSURE)

SEDIMENT TRAP

INSTALLATION REQUIREMENTS

Installation must include a manual shutoff valve, union, 

and plugged 1/8” NPT tap. Locate NPT tap within reach 

for test gauge hook up. NPT tap must be upstream from 

the appliance.

Apply pipe joint sealant lightly to male threads. This will 

prevent excess sealant from going into pipe. Excess 

sealant in pipe could result in a clogged burner injector.

Install sediment trap in supply line as shown below. 

Locate sediment trap where it is within reach for cleaning 

and trapped matter is not likely to freeze. 

A sediment trap prevents moisture and contaminants 

from entering the Outdoor Fire Pit controls. If a sediment 

trap is not installed, or is installed incorrectly, the unit may 

not work properly.

CHECKING GAS CONNECTION

       WARNING: Test all gas piping and connections 

for leaks after installing or servicing. Correct all leaks 

immediately.

       WARNING: Never use an open flame to check for 

a leak. Apply a mixture of liquid soap and water to all 

joints. Bubbles forming on joints while the gas is running 

indicate a leak. Correct all leaks at immediately.

Test Pressures in Excess Of 1/2 psi (3.5 kPa)

This appliance and its individual shutoff valve must be 

disconnected from the gas supply piping system during 

any pressure testing of that system at test pressures in 

excess of ½ psi (3.5 kPa).

Test Pressures Equal To or Less Than 1/2 psi (3.5 kPa)

This appliance must be isolated from the gas supply 

piping system by closing its individual manual shutoff 

valve during any pressure testing of the gas supply piping 

system at test pressures equal to or less than ½ psi (3.5 

kPa).

CONNECTING TO GAS SUPPLY

 WARNING:

A qualified service person must connect 

the appliance to the gas supply. Follow all 

local codes.

CAUTION: 

Use only new black iron or steel pipe. 

Internally tinned copper tubing may be 

used in certain areas. Use pipe of 1/2” 

diameter or greater to allow proper gas 

volume to Outdoor Fire Pit Burner. If pipe 

is too small, undue loss of pressure will 

occur.

INSTALLATION ITEMS NEEDED:

Before installing the Outdoor

Fire Pit, make sure you have all items 

listed bellow:

•  piping (check local codes)

•  sealant

•  manual shutoff valve

•  adjustable (crescent) wrench or pliers

•  sediment trap

•  tee joints

•  pipe wrench

                 

 

Содержание Robata 54 Concrete

Страница 1: ...gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cyllinder not connected for use shall not be stored in the vicinity of this or any other appliance C...

Страница 2: ...1 NFPA 54 or the International Fuel Gas Code 3 Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 4 Do not burn solid fuel in this appli...

Страница 3: ...TRAY GAS ELECTRICAL SUPPLY BODY ROBATA 72 ROBATA 54 1 UNPACK Account for all parts p 15 16 2 FRAGILE Handle with care 3 LEVEL Place on a solid level surface 4 AIR VENTS Do not block ventilation gaps p...

Страница 4: ...OBATA 72 54 CONCRETE FIRE Installation Owner s Manual DIMENSIONS ROBATA 54 22 559 24 610 8 203 54 1372 20 3 4 527 12 1 2 318 22 559 12 1 2 318 SIDE END BOTTOM VENTILATION GAP DO NOT OBSTRUCT BASE OPEN...

Страница 5: ...ROBATA 72 54 CONCRETE FIRE Installation Owner s Manual DIMENSIONS ROBATA 72 SIDE END BOTTOM BASE OPENINGS VENTILATION GAPS DO NOT OBSTRUCT 12 1 2 318 16 3 4 425 24 610 72 1829 22 559 8 203 11 1 4 286...

Страница 6: ...h 57 000 BTU h 80 000 BTU h 77 000 BTU h Inlet Pressure Min 4 5 W C 11 0 W C 4 5 W C 11 0 W C Inlet Pressure Max 10 5 W C 13 0 W C 10 5 W C 13 0 W C Orifice Size 26 43 18 37 Burner Ports 35 35 47 47...

Страница 7: ...rock or tempered glass pebble on top of burner media See page 8 Decorative media should be brought level with the top of the pilot cover An uneven or excessively thick layer of topping can result in...

Страница 8: ...tallation Owner s Manual BURNER MEDIA DECORATIVE TOPPING METAL LID OPTIONAL DECORATIVE TOPPING MEDIA VARIOUS FILL TOPPING TRAY COVER BURNER MEDIA KEEP BELOW LID LINE BURNER MEDIA CRUSHED GLASS NG LAVA...

Страница 9: ...en flame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming on joints while the gas is running indicate a leak Correct all leaks at immediately Test Pressures i...

Страница 10: ...ed service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water Improper installation adjustment alteration service or mainte...

Страница 11: ...the ON position 7 Plug the supplied 24 VAC AC adapter into a 110V power outlet 8 Connect the AC adapter to the AC input plug at the unit 9 Place Burner Assembly in Housing 10 To ignite burner turn on...

Страница 12: ...s 13 14 BURNER ELEMENT AND PILOT Keep the burner and pilot area clean by vacuuming or brushing at least twice a year Make sure the burner porting and burner air openings are free of obstructions at al...

Страница 13: ...PORT In the case of consistently windy conditions a protective glass barrier may be necessary 2 Ensure gas line is thoroughly bled 3 Ensure ventilation holes gaps are not obstructed Unit is smoking s...

Страница 14: ...ed 4 Pilot valve lead is loose disconnected 1 Turn off gas supply or open manual shutoff valve 2 Purge air from the supply line 3 Clean pilot see Cleaning and Maintenance page 12 or replace pilot asse...

Страница 15: ...me 2a Air Shutter 3 Orifice FIT ORI 26 or 18 FIT ORI 37 or 43 4 Media Tray LIN 36 or 48 ASSY A same 5 Burner Tray LIN 36 or 48 ASSY B same 6 Control Box Brackets LIN 36 or 48 ASSY C same 7 Pilot Assem...

Страница 16: ...R E BOX same 2 Dual Solenoid Valve E VAL BASO w LP reg spring 3 3 8 x1 1 2 Nipple 4 3 8 Bulkhead Union 5 3 8 Union 6 Pilot Assembly PIL E 410 PIL E 410LP 7 Shrink fit Cord Grip 8 Ignition Control Boar...

Страница 17: ...ED PARTS LIST Wiring Diagram 1 2 3 4 5 10 6 7 11 8 9 MAIN GND VALVE PILOT GND BURNER GND 24V SENSE SPARK AC POWER ADAPTER INPUT AC 120V 60 Hz 8A OUTPUT 24 VAC 750 mA CHASSIS GROUND PILOT PIL E 410 OR...

Страница 18: ...rranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 fire pit burner assembly damaged b...

Отзывы: