background image

15

ROBATA 72/54 CONCRETE FIRE | Installation & Owner’s Manual

ILLUSTRATED PARTS LIST

WARNING: Failure to position parts in accordance with diagrams or failure 

to use parts specifically approved for this appliance may result in property 

damage or personal injury.

REPLACEMENT PARTS ARE AVAILABLE FROM PALOFORM

Natural Gas

Propane

1

Pilot Cover

LIN-EPC

same

1a

Pilot Shroud

LIN-EPC

same

2

LIN-(36 or 48) Burner Tube

LIN-(36 or 48)-ASSY

same

2a

Air Shutter

-

-

3

Orifice

FIT-ORI-(26 or 18)

FIT-ORI-(37 or 43)

4

Media Tray

LIN-(36 or 48)-ASSY-A

same

5

Burner Tray

LIN-(36 or 48)-ASSY-B

same

6

Control Box Brackets

LIN-(36 or 48)-ASSY-C

same

7

Pilot Assembly

PIL-E-410

PIL-E-410LP

8

Control Box

see drawing p. 16

same

9

Flex Connector

CON-SS-5MM-24

same

10

Burner Media (not shown)

Crushed Glass

Lava Pebbles

11

Topping Media (not shown)

Various

Various

12

Fabric Cover (not shown)

COV-ROB(54 or 72)-LC

same

13

Metal Top and Cover

see p. 3

same

14

Concrete Vessel (not shown)

ROB54-(colour code)

ROB72-(colour code)

same

15

Power Adapter 120V-NA 

(not shown)

E-POW-24VAC

same

1

1a

2

2a 

4

5

6

7

8

9

Содержание Robata 54 Concrete

Страница 1: ...gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cyllinder not connected for use shall not be stored in the vicinity of this or any other appliance C...

Страница 2: ...1 NFPA 54 or the International Fuel Gas Code 3 Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 4 Do not burn solid fuel in this appli...

Страница 3: ...TRAY GAS ELECTRICAL SUPPLY BODY ROBATA 72 ROBATA 54 1 UNPACK Account for all parts p 15 16 2 FRAGILE Handle with care 3 LEVEL Place on a solid level surface 4 AIR VENTS Do not block ventilation gaps p...

Страница 4: ...OBATA 72 54 CONCRETE FIRE Installation Owner s Manual DIMENSIONS ROBATA 54 22 559 24 610 8 203 54 1372 20 3 4 527 12 1 2 318 22 559 12 1 2 318 SIDE END BOTTOM VENTILATION GAP DO NOT OBSTRUCT BASE OPEN...

Страница 5: ...ROBATA 72 54 CONCRETE FIRE Installation Owner s Manual DIMENSIONS ROBATA 72 SIDE END BOTTOM BASE OPENINGS VENTILATION GAPS DO NOT OBSTRUCT 12 1 2 318 16 3 4 425 24 610 72 1829 22 559 8 203 11 1 4 286...

Страница 6: ...h 57 000 BTU h 80 000 BTU h 77 000 BTU h Inlet Pressure Min 4 5 W C 11 0 W C 4 5 W C 11 0 W C Inlet Pressure Max 10 5 W C 13 0 W C 10 5 W C 13 0 W C Orifice Size 26 43 18 37 Burner Ports 35 35 47 47...

Страница 7: ...rock or tempered glass pebble on top of burner media See page 8 Decorative media should be brought level with the top of the pilot cover An uneven or excessively thick layer of topping can result in...

Страница 8: ...tallation Owner s Manual BURNER MEDIA DECORATIVE TOPPING METAL LID OPTIONAL DECORATIVE TOPPING MEDIA VARIOUS FILL TOPPING TRAY COVER BURNER MEDIA KEEP BELOW LID LINE BURNER MEDIA CRUSHED GLASS NG LAVA...

Страница 9: ...en flame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming on joints while the gas is running indicate a leak Correct all leaks at immediately Test Pressures i...

Страница 10: ...ed service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water Improper installation adjustment alteration service or mainte...

Страница 11: ...the ON position 7 Plug the supplied 24 VAC AC adapter into a 110V power outlet 8 Connect the AC adapter to the AC input plug at the unit 9 Place Burner Assembly in Housing 10 To ignite burner turn on...

Страница 12: ...s 13 14 BURNER ELEMENT AND PILOT Keep the burner and pilot area clean by vacuuming or brushing at least twice a year Make sure the burner porting and burner air openings are free of obstructions at al...

Страница 13: ...PORT In the case of consistently windy conditions a protective glass barrier may be necessary 2 Ensure gas line is thoroughly bled 3 Ensure ventilation holes gaps are not obstructed Unit is smoking s...

Страница 14: ...ed 4 Pilot valve lead is loose disconnected 1 Turn off gas supply or open manual shutoff valve 2 Purge air from the supply line 3 Clean pilot see Cleaning and Maintenance page 12 or replace pilot asse...

Страница 15: ...me 2a Air Shutter 3 Orifice FIT ORI 26 or 18 FIT ORI 37 or 43 4 Media Tray LIN 36 or 48 ASSY A same 5 Burner Tray LIN 36 or 48 ASSY B same 6 Control Box Brackets LIN 36 or 48 ASSY C same 7 Pilot Assem...

Страница 16: ...R E BOX same 2 Dual Solenoid Valve E VAL BASO w LP reg spring 3 3 8 x1 1 2 Nipple 4 3 8 Bulkhead Union 5 3 8 Union 6 Pilot Assembly PIL E 410 PIL E 410LP 7 Shrink fit Cord Grip 8 Ignition Control Boar...

Страница 17: ...ED PARTS LIST Wiring Diagram 1 2 3 4 5 10 6 7 11 8 9 MAIN GND VALVE PILOT GND BURNER GND 24V SENSE SPARK AC POWER ADAPTER INPUT AC 120V 60 Hz 8A OUTPUT 24 VAC 750 mA CHASSIS GROUND PILOT PIL E 410 OR...

Страница 18: ...rranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 fire pit burner assembly damaged b...

Отзывы: