6
ROBATA 72/54 CONCRETE FIRE | Installation & Owner’s Manual
SPECIFICATIONS & CLEARANCES
72”
1829
8”
203
ROBATA 54
NATURAL GAS
ROBATA 54
PROPANE
ROBATA 72
NATURAL GAS
ROBATA 72
PROPANE
Burner Model #
LIN-36
LIN-36P
LIN-48
LIN-48P
Max Heat Input
60,000 BTU/h
57,000 BTU/h
80,000 BTU/h
77,000 BTU/h
Inlet Pressure - Min,
4.5" W.C
11.0" W.C.
4.5" W.C
11.0" W.C.
Inlet Pressure - Max. 10.5” W.C.
13.0” W.C.
10.5” W.C.
13.0” W.C.
Orifice Size
26
43
18
37
Burner Ports
35
35
47
47
Port Size
1/8"
1/8"
1/8"
1/8"
Electrical
120V 15A Outdoor Receptacle - Dedicated Circuit with Wall Switch. Burner
connects via an AC adapter. Must be installed and grounded in accordance
with local codes.
MINIMUM CLEARANCES TO COMBUSTIBLES
72”
1829
8”
203