palintest Pooltest 3 Скачать руководство пользователя страница 15

 

 

30

2

Take  a  sample  of  the  water  and  measure  the  total 

alkalinity.  Using  the  table  below,  read  off  the 

factor  which  corresponds  nearest  to  the  total 

alkalinity 

value 

measured. 

Record 

this 

Total 

Alkalinity Factor (Line 2). 

3

Take  a  sample  of  the  water  and  measure  the  pH. 

Record the actual pH value (Line 3). 

4

Add  together  the  values  of  lines  1,  2  and  3.  This 

gives  the  Palintest  Balanced  Water  Index  for  the 

water. Compare the index obtained with the Water 

Balance 

Condition 

Table 

overleaf. 

This 

table 

indicates  whether  the  water  is  in  balance,  and  if 

not, the recommended action to be taken :- 

 

 

 

Calcium 

Hardness/Alkalinity 

as mg/l CaCO

3

 

Factor 

Calcium 

Hardness/Alkalinity 

as mg/l CaCO

3

 

 

Factor 

20 

1.0 

200 

2.0 

30 

1.2 

250 

2.1 

40 

1.3 

300 

2.2 

50 

1.4 

350 

2.25 

66 

1.5 

400 

2.3 

80 

1.6 

500 

2.4 

90 

1.65 

550 

2.45 

100 

1.7 

600 

2.5 

125 

1.8 

700 

2.55 

150 

1.9 

800 

2.6 

 

 

31

Calculation: 

Line 1   Calcium Hardness Factor  

Line 2   + Alkalinity Factor 

Line 3   + actual pH 

 

Sum      = 

 

Index 

Water Balance 

Condition 

Recommendation 

Below 9.6 

Highly Corrosive 

Increase pH to 7.5 - 7.8.  

Increase Calcium Hardness to at 

least 50 mg/l.  

Increase Total Alkalinity to 100 

mg/l or higher as necessary.  

Retest Water Balance.  

9.6 - 10.5 

Corrosive 

10.6 - 10.9 

Acceptable 

Balance 

Retest water regularly.  

11.0 - 11.2 

Ideal Balance 

No action required.  

11.3 - 11.6 

Acceptable 

Balance 

Retest water regularly.  

11.7 - 12.6 

Scale Forming 

Decrease pH to 7.2 - 7.5. 

Decrease Total Alkalinity to 150 

mg/l or lower as necessary.  

Retest Water Balance.  

Above 12.6 

Highly Scale 

Forming 

 

 

 

 

 

Содержание Pooltest 3

Страница 1: ...lts for the testing of water Our instruments are of the highest quality and fully waterproof Palintest s experience built up over the last 50 years is the reason why our instruments and reagents are u...

Страница 2: ...Rods Test Tube Brush Photometer Tubes Reagents Chlorine Free and Total pH Phenol Red Cyanuric Acid Alkalinity Calcicol Bromine For re ordering codes and accessories please see Section 6 If you have b...

Страница 3: ...easurement between test samples and colour standards a colorimeter can be used for quantitative measurement of the amount of coloured light absorbed by a sample with reagents added in reference to a u...

Страница 4: ...l quantities of red light pass through the solution 9 Blanks and Samples Palintest photometers use a BLANK tube to set the instrument to blank and a SAMPLE tube to take the reading A BLANK tube is a t...

Страница 5: ...drips or condensation before placing in the photometer 5 Do not leave tubes standing in the photometer test chamber Remove the tubes immediately after each test 6 Immediately wipe up any drips or spil...

Страница 6: ...1 5 mg l range Cl2 10 Chlorine Free and Total 0 01 10 mg l range pH pH pH Units CNA Cyanuric Acid Alk T Alkalinity Total Calc Calcium Hardness Calc NaCl Calcium Hardness Salt Water Pools Only Br Bromi...

Страница 7: ...ion remaining from the Free Chlorine test 2 If any non chlorine shock treatment chemicals have been added to the pool see additional notes below 3 Add one DPD No 3 tablet or DPD XT for high range inst...

Страница 8: ...cal Palintest branch distributor or see www palintest com Reagents AP 011 DPD No 1 Tablets Low Range AP 013 DPD XF Tablets High Range AP 031 1 DPD No 3 Tablets Low Range AP 033 1 DPD XT Tablets High R...

Страница 9: ...sample to the 10 ml mark 2 Add one Alkaphot tablet crush and mix until all the particles have dissolved It is important to ensure that all of the tablet particles have dissolved otherwise the result...

Страница 10: ...standard Calcicol test is still valid Magnesium hardness up to 200 mg l as CaCO3 does not interfere with the test Iron at levels above 10 mg l may cause low results Zinc above 5 mg l may cause high r...

Страница 11: ...ng systems is recommended The crossed out wheeled bin symbol on the meter encourages you to use these systems when disposing of this equipment Error Messages The photometer will display an error messa...

Страница 12: ...ight transmission and affect readings To clean the optics gently clean the internal surfaces of the optics with a soft non abrasive cloth Do not use solvents Deposits may be removed with a slightly da...

Страница 13: ...S are used to oxidise organic contaminants in the water and regenerate free chlorine from chloramines Typical products are Oxybrite Oxysure and Purolyte Plus 27 Excess MPS reacts in the DPD test It do...

Страница 14: ...mg l Ca multiply by 0 4 29 Bromine For most purposes it is sufficient to simply measure the total bromine residual using DPD No 1 tablets since both free and combined bromine are active disinfectants...

Страница 15: ...ness Alkalinity as mg l CaCO3 Factor 20 1 0 200 2 0 30 1 2 250 2 1 40 1 3 300 2 2 50 1 4 350 2 25 66 1 5 400 2 3 80 1 6 500 2 4 90 1 65 550 2 45 100 1 7 600 2 5 125 1 8 700 2 55 150 1 9 800 2 6 31 5 C...

Страница 16: ...the European CE Mark of Compliance for electro magnetic compatibility EMC 33 Sample Dilution and Collection When the test result is outside the concentration range of the test the photometer will disp...

Страница 17: ...087 AP 087 Alkaphot PM 188 AP 188 Calcicol PM 252 AP 252 EDTA Tablets AT 090 DPD Oxystop AP 017 Accessories Description Product Code Test Tube Brush PT 663 Replacement Photometer Tubes x5 PT 555 Photo...

Отзывы: